2022
DOI: 10.1051/matecconf/202235400044
|View full text |Cite
|
Sign up to set email alerts
|

Modular automation cabinet for proactive monitoring in ATEX Zone 2

Abstract: The paper presents an automation system dedicated to oil & gas machinery applications, such as electrical gas compressors. The future aim is to introduce it into the Romanian oil & gas industry. The system consists of a low size cabinet and its dependencies, which can be used in ATEX Zone 2. The electronic equipment is dimensioned and chosen according to the standards in force, so that the limited current and voltage requirements for methane gas to be met. The key feature is that this system complies w… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
1

Relationship

3
2

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 6 publications
(6 reference statements)
0
3
0
Order By: Relevance
“…Another critical factor that has led us to the proposal of the paper was that, in the current state, manual maneuvers for decreasing the intake pressure are required to facilitate the startup of a screw compressor, such as opening the discharge valve of the station and continually purging an quantity of gas, or half-opening the manual valve placed on the station pipe to induce pressure drop, while the compressor start command is being initialized. These actions necessitate the presence of two operators and do not always guarantee that the compressor will start [9][10][11][12].…”
Section: Analysing Critical Factorsmentioning
confidence: 99%
“…Another critical factor that has led us to the proposal of the paper was that, in the current state, manual maneuvers for decreasing the intake pressure are required to facilitate the startup of a screw compressor, such as opening the discharge valve of the station and continually purging an quantity of gas, or half-opening the manual valve placed on the station pipe to induce pressure drop, while the compressor start command is being initialized. These actions necessitate the presence of two operators and do not always guarantee that the compressor will start [9][10][11][12].…”
Section: Analysing Critical Factorsmentioning
confidence: 99%
“…A control cabinet [17,18] was designed for the valve, for the monitoring and control of the valve, both for testing its functionality on the bench with brake simulating mechanical load (Fig. 2), as well as testing its operation on the skid (Fig.…”
Section: Overview On Valve Test Bench and Proposed Solutionmentioning
confidence: 99%
“…Harvesting vibration energy mainly aims to eliminate cabling in the sites with difficult conditions or space constraints. A possible application would be powering sensor nodes in hazardous locations [12], where regulations are applied for using costly explosion-proof certified equipment and cabling in the field, subjected to the ATEX Directive in Europe.…”
Section: Introductionmentioning
confidence: 99%