Modified SEPIC Converter Performance for Grid-connected PV Systems under Various Conditions

Abstract: Step-up converter is widely used to increase DC voltage level on PV systems either off-grid or grid connected. One of the step-up converters often used in PV systems is SEPIC converter. To improve its performance, many SEPIC converters have been modified. However, performance on various conditions has not been further investigated. In this study, the modified SEPIC converter was investigated under various change conditions for grid-connected PV applications. This converter was modelled and simulated using PSIM… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
15
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(15 citation statements)
references
References 39 publications
0
15
0
Order By: Relevance
“…Thus, the losses in modified Cuk DC-DC power converter is lower than the conventional ones. In (16,17) show that for the same output voltages, the power loss in modified Cuk DC-DC power converter is lower than the conventional boost DC-DC power converter.…”
Section: Modified Cuk Dc-dc Power Convertermentioning
confidence: 97%
See 1 more Smart Citation
“…Thus, the losses in modified Cuk DC-DC power converter is lower than the conventional ones. In (16,17) show that for the same output voltages, the power loss in modified Cuk DC-DC power converter is lower than the conventional boost DC-DC power converter.…”
Section: Modified Cuk Dc-dc Power Convertermentioning
confidence: 97%
“…Figure 2 shows that a DC-DC converter is used as an interface between the DC grid and DC energy sources and between the DC grid and battery energy storage. Various DC-DC power converters for these purposes have been proposed in the literature [1][2][3][4][5][6][7][8][9][10][11][12][13][14][15][16][17][18][19][20]. Though the DC-DC converter can be isolated or nonisolated, the nonisolated DC-DC converter is preferred because of power loss consideration.…”
Section: Introductionmentioning
confidence: 99%
“…Applying partial fraction decomposition and the inverse Laplace transformation to (29) leads to the timedomain waveform reported in (31).…”
Section: Design Of the Bus Voltage Behaviormentioning
confidence: 99%
“…To design the bus voltage behavior, the following performance criteria are defined: maximum bus voltage deviation ∆vdc and settling time ts after a step current perturbation with amplitude |I dc |. The first performance criterion is analyzed by deriving the time-domain waveform (31) as (32):…”
Section: Design Of the Bus Voltage Behaviormentioning
confidence: 99%
See 1 more Smart Citation