Modification of pulse sequences reduces occupational exposure from MRI switched gradient fields: Preliminary results

Abstract: The gradient fields in magnetic resonance imaging (MRI) will in some circumstances exceed the ICNIRP guidelines of occupational electromagnetic field exposure when personnel are near the scanner during MRI scanning. In this work we have shown that using commercially available modified sequences for noise reduction purposes, exposure will decrease by a factor of 1.5 with preserved image quality. This is a first step toward optimizing occupational exposure within the scanner room without affecting image quality.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
20
0

Year Published

2012
2012
2019
2019

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 13 publications
(23 citation statements)
references
References 2 publications
3
20
0
Order By: Relevance
“…In particular, the “whisper” gradient mode improves patient safety, reducing SR p to 75.3 T m ‐1 s ‐1 . More generally, all experimental findings highlight, in accordance with previous studies [Wilén et al, ; Trevisan et al, ; Frankel et al, ], that not only different types of sequences, but also scan settings can affect SR p values. In particular, regardless of the type of sequence, the “fast” gradient mode is always associated with increased slew rate.…”
Section: Resultssupporting
confidence: 92%
“…In particular, the “whisper” gradient mode improves patient safety, reducing SR p to 75.3 T m ‐1 s ‐1 . More generally, all experimental findings highlight, in accordance with previous studies [Wilén et al, ; Trevisan et al, ; Frankel et al, ], that not only different types of sequences, but also scan settings can affect SR p values. In particular, regardless of the type of sequence, the “fast” gradient mode is always associated with increased slew rate.…”
Section: Resultssupporting
confidence: 92%
“…Sensitive patients may require more advanced adjustments to a sequence, such as SAR‐reducing adjustments to the RF field, to prevent heating of certain kinds of implants or fever in patients who have a reduced ability to regulate body heat. For patients with sensitive hearing, a sequence can be run in noise‐reducing mode, which, in addition to reducing the noise level, also reduces the time derivative of the gradient magnetic field [Wilén et al, ].…”
Section: Discussionmentioning
confidence: 99%
“…Early measurements involving a single search coil established that significant gradient fringe fields exist beyond the bore of the scanner [76]. These results have been extended using three-axis calibrated meters [6,70,74,[77][78][79][80]. Table 6 summarises all the known results for exposure measurements at the entrance of the bore in terms of peak B, dB/dt or percentage of the ICNIRP and NRPB (old ICNIRP) RLs.…”
Section: Time-varying Gradient Fieldsmentioning
confidence: 99%