2015
DOI: 10.12700/aph.12.8.2015.8.6
|View full text |Cite
|
Sign up to set email alerts
|

Models for Force Control in Telesurgical Robot Systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
5
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 26 publications
(5 citation statements)
references
References 24 publications
0
5
0
Order By: Relevance
“…The concept of the qualification method is based on the theoretical introduction of a so-called performance-function (к), which provides a percentile value of the measured rotation (ρpr (φ)) of a commercial prosthesis relative to the referencerotation (ρref (φ)). This has been introduced by Katona et al [8]: (1) where: In order to estimate a performance-function of an arbitrary TKR, e.g. with regard to rotation, both the rotation function (ρpr (φ)) of the examined prosthesis and the reference-rotation function (ρref (φ)) needed to be determined.…”
Section: Concept Of Qualificationmentioning
confidence: 99%
See 1 more Smart Citation
“…The concept of the qualification method is based on the theoretical introduction of a so-called performance-function (к), which provides a percentile value of the measured rotation (ρpr (φ)) of a commercial prosthesis relative to the referencerotation (ρref (φ)). This has been introduced by Katona et al [8]: (1) where: In order to estimate a performance-function of an arbitrary TKR, e.g. with regard to rotation, both the rotation function (ρpr (φ)) of the examined prosthesis and the reference-rotation function (ρref (φ)) needed to be determined.…”
Section: Concept Of Qualificationmentioning
confidence: 99%
“…A wide range of choice regarding the brands (Stryker©, Zimmer©, BioTech©, CeramTec© or Sanatmetal©) and sizes (S, M, L, XL, etc.) of commercial knee replacements and supporting telesurgical technologies [1] are available for surgeons to carry out knee operations to restore closely the same kinematics of the physiological knee joint. Multiple, substantial studies have been published about how total knee replacement (TKR) design affects the kinetics [2,3] and kinematics [4] of the knee joint.…”
Section: Introductionmentioning
confidence: 99%
“…Compared with surgical robots such as Da Vinci ® [7,8], which need appropriate modeling of the interaction between the manipulated tissues and the instruments, the interventional surgical robot is relatively simple and are mainly developed to realize the delivery and rotation of the guide wire/catheter in the blood vessel. Reliability and ease of use are the core competitiveness of medical robots.…”
Section: Introductionmentioning
confidence: 99%
“…The excellent scientific contributions and management activity of Prof. Imre J. Rudas are kindly acknowledged. Some representative well-accepted joint papers in this regard are given in (Pozna et al, 2010 [20], (Haidegger et al, 2012) [21], (Precup et al, 2012) [22] and (Takács et al, 2015) [23].…”
Section: Introductionmentioning
confidence: 99%