Abstract:Accident analysis of fusion facilities is important part of safety assessment. Validated computer codes are required to perform such analysis. At present ASTEC code is being actively developed by IRSN to include features required for safety analysis of fusion facilities. This paper presents detailed analysis of P1 test performed at ICE test facility using CPA module of ASTEC code. Results of performed analysis confirmed that ASTEC could be successfully applied for analysis of loss of coolant accidents in fusio… Show more
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.