2010
DOI: 10.1016/j.fluid.2010.02.004
|View full text |Cite
|
Sign up to set email alerts
|

Modeling the phase equilibria of hydrogen sulfide and carbon dioxide in mixture with hydrocarbons and water using the PCP-SAFT equation of state

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
64
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 70 publications
(68 citation statements)
references
References 106 publications
(84 reference statements)
2
64
0
Order By: Relevance
“…Pure VLE data for H 2 were excluded from the regressed database, because they correspond to a very low temperature (<33 K), i.e., where the ortho/para ratio of H 2 is very different from that of the conditions of interest for industrial purposes [48]. As suggested in the work by Tang and Gross [37], H 2 S was modeled as an associative molecule without polar interactions. The parameters of CO, H 2 , O 2 and H 2 S used in this work are summarized in Table 2.…”
Section: Modeling Strategy and Model Parametersmentioning
confidence: 99%
See 1 more Smart Citation
“…Pure VLE data for H 2 were excluded from the regressed database, because they correspond to a very low temperature (<33 K), i.e., where the ortho/para ratio of H 2 is very different from that of the conditions of interest for industrial purposes [48]. As suggested in the work by Tang and Gross [37], H 2 S was modeled as an associative molecule without polar interactions. The parameters of CO, H 2 , O 2 and H 2 S used in this work are summarized in Table 2.…”
Section: Modeling Strategy and Model Parametersmentioning
confidence: 99%
“…(2)). Due to the dissolution of a gas in an IL, the dielectric Table 2 PC-SAFT parameters for CO [27], H2 [48], O2 [36] and H2S [37] used in this work. constant of the medium will change from the vacuum value (for a pure IL) to a certain value, which is related to the amount of gas dissolved in the IL.…”
Section: Modeling Strategy and Model Parametersmentioning
confidence: 99%
“…For the PC-SAFT EoS, the three purecomponent parameters (i.e., temperature independent segment diameter , depth of the potential , and number of segments per chain m ) of the non-associating compounds, CH 4 and CO 2 , were taken from Gross and Sadowski [2] whereas for the associating compounds, H 2 S and H 2 O, these three pure-component parameters plus the two additional association parameters (i.e., the association energy AB and volume AB for each site-site interaction) were taken from Tang and Gross [18]. Table 1 presents the physical properties of the four compounds forming the mixture studied as well as the values of the molecular parameters for the non-associating and associating compounds characterizing the PC-SAFT EoS.…”
Section: Results and Discusssionmentioning
confidence: 99%
“…This approach has been applied to CO 2 -H 2 O, H 2 S-H 2 O, and H 2 S-CO 2 systems. For example, Perfetti and co-workers (Perfetti et al, 2008a,b) and Li and Firoozabadi (2009) Tang and Gross (2010) used PCP-SAFT for the H 2 S-CO 2 system. However, to the best of our knowledge, no EOS has been developed for the quaternary H 2 S-CO 2 -H 2 O-NaCl system with any approaches.…”
Section: Introductionmentioning
confidence: 99%