The XIX International Conference on Electrical Machines - ICEM 2010 2010
DOI: 10.1109/icelmach.2010.5607870
|View full text |Cite
|
Sign up to set email alerts
|

Modeling of saturated synchronous generator based on steady-state operating data

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
7
0

Year Published

2014
2014
2020
2020

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(8 citation statements)
references
References 17 publications
1
7
0
Order By: Relevance
“…It is possible to see that the starting electro-mechanical torque for the saturated conditions has a lower magnitude than the one for the saturated one. Furthermore, the torque frequency and phase are not affected by the saturation validating previous results in saturation modeling [16], [17], [26], [27].…”
Section: B Real Time Resultssupporting
confidence: 85%
See 1 more Smart Citation
“…It is possible to see that the starting electro-mechanical torque for the saturated conditions has a lower magnitude than the one for the saturated one. Furthermore, the torque frequency and phase are not affected by the saturation validating previous results in saturation modeling [16], [17], [26], [27].…”
Section: B Real Time Resultssupporting
confidence: 85%
“…One of the most influential factors which influences the dynamic and steady state response of a machine is saturation. Although this topic has been studied extensively for offline simulations [16], [17], it is considerably new in its implementation for real time simulation.…”
Section: Introductionmentioning
confidence: 99%
“…In many cases, the generator modeling includes field winding together with the control system to evaluate time domain performance (Barakat et al, 2011). However, to calculate the frequency response, the synchronous generator inductance, stable armature ground capacitances and the balanced operation of the generator are particularly important (Barakat et al, 2011, Despalatovic et al, 2011, Hadi and Wijaya, 2013. Figure 2 shows the circuit corresponding to the modeling of the generator:…”
Section: Methodsmentioning
confidence: 99%
“…Generators can be modeled in several ways [23][24]; in this research work they are modeled by means of sinusoidal voltage sources behind impedances with a fundamental frequency of 60 Hz and 1.41 per unit peak amplitude; the transmission lines are modeled with an equivalent pi model, and the electrical linear loads can be modeled in different ways [7]; in this work they are represented by a parallel R-XL network.…”
Section: B Experimental 5-node Power System Modelingmentioning
confidence: 99%