Modeling of Pump Operation Conditions in Gravity-Pressure Combined Systems

Abstract: The paper presents the problem of working conditions in gravitationalpressure systems simulation. The practical example takes into account the dynamical analysis of a system equipped with 10 pump stations with different functions. Both local press stations, local stations for shallowing network and transit pumping stations between the towns were used. The model allowed to optimize the active volume of the pump station tanks, the selection of pumps, including the frequency of power on and the time of holding th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2018
2018
2018
2018

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(3 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…Values obtained for this variant are not acceptable. As opposed to the example provided in literature [3], there was no necessity to replace the subsystem pump type 3 characteristics [4] -pressure pipeline, with type 4 characteristics [4]. The necessity to make such a simplification occurs mainly in the case of long pressure pipelines where more than one "high" point is present, where it is necessary to install an air relief valve.…”
Section: Discussion Of Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Values obtained for this variant are not acceptable. As opposed to the example provided in literature [3], there was no necessity to replace the subsystem pump type 3 characteristics [4] -pressure pipeline, with type 4 characteristics [4]. The necessity to make such a simplification occurs mainly in the case of long pressure pipelines where more than one "high" point is present, where it is necessary to install an air relief valve.…”
Section: Discussion Of Resultsmentioning
confidence: 99%
“…Omission of protection against backflow results in the backup of sewage to the initial well (in Epa SWMM, each calculation node is treated as a well connected directly with the atmosphere). An example of the analysis of the concept of sewage discharge in the commune of Niegosławice [3] using the simulation model was verified by calculations realized using the Epanet programme. The obtained results made it possible to state that: -average pump efficiencies are comparable in the majority of cases, -in the case of pumping stations located at the end of a system (including the main pumping station discharging sewage to an existing system), there is an anomaly in the form of an unjustified increase in pump efficiency to the maximum value of pump efficiency input into the model, -the mentioned anomaly may periodically lead to a distortion during the time of analysing the duration of an individual pumping cycle (rapid emptying of active volume).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation