2011
DOI: 10.3384/ecp11063353
|View full text |Cite
|
Sign up to set email alerts
|

Modeling of Coal-Fired Power Units with ThermoPower Focussing on Start-Up Process

Abstract: Governmental encouragement of renewable energies like wind energy led to an extensive increase of installed wind energy capacity worldwide. In order to allow a complete integration of this continuously fluctuating energy source, it is necessary to have a highly flexible operation management as well as power stations which are able to follow the high dynamics of the wind power production.In this context the component fatigue and operational limitations of current and future power stations have to be investigate… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
4
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 2 publications
0
4
0
Order By: Relevance
“…The decision to exclude the highest-pressure feedwater preheater was proposed as a strategy for full-load operation retention, when superheated and/or reheated steam temperature declined. An non-conventional load change from 40% to 100% load was simulated in [90]. A coal-fired power plant detailed model was developed with Modelica ® Modelon ThermoPower library.…”
Section: Undesired Operation and Accidentsmentioning
confidence: 99%
See 1 more Smart Citation
“…The decision to exclude the highest-pressure feedwater preheater was proposed as a strategy for full-load operation retention, when superheated and/or reheated steam temperature declined. An non-conventional load change from 40% to 100% load was simulated in [90]. A coal-fired power plant detailed model was developed with Modelica ® Modelon ThermoPower library.…”
Section: Undesired Operation and Accidentsmentioning
confidence: 99%
“…Each component of the plant and the whole plant was validated against operational data. One soft start- An non-conventional load change from 40% to 100% load was simulated in [90]. A coal-fired power plant detailed model was developed with Modelica ® Modelon ThermoPower library.…”
Section: Undesired Operation and Accidentsmentioning
confidence: 99%
“…• A 550MW anthracite coal-fired power plant model developed using the ThermoPower library [4] presented by Meinke et al [5]. It consists of a predefined water/steam cycle, boiler combustion chamber and air passage power plant components that work in conjunction with control schemes.…”
Section: Introductionmentioning
confidence: 99%
“…Similar models of a hard coal red power plant and a combined cycle gas turbine power plant have been developed previously for dierent applications (e.g. [1], [2] and [3]). The • Low pressure preheater bypass: In this mode the power plant increases its electrical output by throttling the valves to the low pressure preheaters and the feedwater tank.…”
Section: Introductionmentioning
confidence: 99%