2018
DOI: 10.1016/j.energy.2018.09.074
|View full text |Cite
|
Sign up to set email alerts
|

Modeling of a new absorption heat pump-transformer used to produce heat and power simultaneously

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(3 citation statements)
references
References 33 publications
0
3
0
Order By: Relevance
“…Finally, Figure 13 shows the variation of the coefficients of performance as a function of the condensation and evaporation temperatures at a generation temperature of 56 • C. As was expected, further reducing the thermal source reduced the operating conditions of the half-effect cycle. This was mainly due to the crystallization range of the working mixture, which restricted the operation of the thermodynamic cycle [31]. For these conditions, it was no longer possible to operate the thermodynamic cycle at condensation temperatures above 35 • C. Figures 14 and 15 show the analysis of the exergy efficiency for the operating conditions established in Table 2.…”
Section: Analysis Of Cop Of the Half-effect Cyclementioning
confidence: 99%
See 1 more Smart Citation
“…Finally, Figure 13 shows the variation of the coefficients of performance as a function of the condensation and evaporation temperatures at a generation temperature of 56 • C. As was expected, further reducing the thermal source reduced the operating conditions of the half-effect cycle. This was mainly due to the crystallization range of the working mixture, which restricted the operation of the thermodynamic cycle [31]. For these conditions, it was no longer possible to operate the thermodynamic cycle at condensation temperatures above 35 • C. Figures 14 and 15 show the analysis of the exergy efficiency for the operating conditions established in Table 2.…”
Section: Analysis Of Cop Of the Half-effect Cyclementioning
confidence: 99%
“…As was expected, further reducing the thermal source reduced the operating conditions of the half-effect cycle. This was mainly due to the crystallization range of the working mixture, which restricted the operation of the thermodynamic cycle [31]. For these conditions, it was no longer possible to operate the thermodynamic cycle at condensation temperatures above 35 °C.…”
Section: Appl Sci 2019 9 X For Peer Reviewmentioning
confidence: 99%
“…On the other hand, Hernández-Magallanes et al [20] proposed a new cycle integrating a heat transformer with a heat pump capable of producing electric power and useful heat, simultaneously. This cycle was modeled considering its operation with the working pair NH 3 -LiNO 3 .…”
Section: Theoretical Investigations About Advanced Heat Transformersmentioning