2019
DOI: 10.1109/tpwrs.2018.2890540
|View full text |Cite
|
Sign up to set email alerts
|

Modeling and Formulation of Delayed Cyber-Physical Power System for Small-Signal Stability Analysis and Control

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
13
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 30 publications
(17 citation statements)
references
References 38 publications
0
13
0
Order By: Relevance
“…x y (12) Notably, unlike the model for centralized control mode in [15], the power system in distributed control needs to consider not only the local measurement delay and execution delay but also the communication delays between different agents; thus, we establish the abovementioned distributed information flow model. As stated in the general model of a dynamic power system, the power flow equation is memoryless.…”
Section: Modeling Of a Distributed Cppsmentioning
confidence: 99%
“…x y (12) Notably, unlike the model for centralized control mode in [15], the power system in distributed control needs to consider not only the local measurement delay and execution delay but also the communication delays between different agents; thus, we establish the abovementioned distributed information flow model. As stated in the general model of a dynamic power system, the power flow equation is memoryless.…”
Section: Modeling Of a Distributed Cppsmentioning
confidence: 99%
“…Notably, unlike the model for centralized control mode in [15], the power system in distributed control needs to consider not only the local measurement delay and execution delay but also the communication delays between different agents; thus, we establish the abovementioned distributed information flow model.…”
Section: Modeling Of a Distributed Cppsmentioning
confidence: 99%
“…In view of practical points, CPSs are widely used in intelligent transportation [1,2], smart grid [3][4][5][6], environmental monitoring [7,8] and so on. CPSs have obtained much attention recently, in which various problems such as secure state estimation [9][10][11][12][13][14][15][16][17], stability analysis [18][19][20][21][22] and fault detection [23][24][25][26][27] have been addressed. For example, the state and attack estimation problems for CPSs under actuator and sensor attacks and the disturbances have been investigated in [10].…”
Section: Introductionmentioning
confidence: 99%
“…[15] provides an estimator for a CPS with limited communication resources, sensor saturation and denial-of-service attacks. In [20], the stability for a delayed cyber-physical power system is enhanced by combing with presented delay emerge properties. [26] proposes an attack detection scheme using Kalman filter through residual-based attack detection procedures.…”
Section: Introductionmentioning
confidence: 99%