2020
DOI: 10.15376/biores.15.4.7443-7457
|View full text |Cite
|
Sign up to set email alerts
|

Modeling and dynamic characteristics of the dense phase region of a biomass-fired circulating fluidized bed combustion system using Modelica

Abstract: Using Modelica language, a mathematical model combining static and dynamic contributions of the dense phase region of a 130 t/h biomass circulating fluidized bed boiler combustion system was established on MWorks simulation platform. The mathematical model adopted modular packaging to increase the universality of the model, and it used an implicit, high-order, and multi-step Dassl integration algorithm to conduct the simulation. Under the design condition parameters, the relative error between the bed temperat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2021
2021
2021
2021

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 23 publications
0
2
0
Order By: Relevance
“…The changes of these operating parameters have a complex interleaving effect on the BCFB. At the same time, the safety requirement of boiler systems is high and some system parameters are difficult to be measured directly . It is difficult to obtain the coupling relationship between the above-mentioned factors and the bed temperature, bed pressure, and pollutant concentration in flue gas through simple tests.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The changes of these operating parameters have a complex interleaving effect on the BCFB. At the same time, the safety requirement of boiler systems is high and some system parameters are difficult to be measured directly . It is difficult to obtain the coupling relationship between the above-mentioned factors and the bed temperature, bed pressure, and pollutant concentration in flue gas through simple tests.…”
Section: Resultsmentioning
confidence: 99%
“…At the same time, the safety requirement of boiler systems is high and some system parameters are difficult to be measured directly. 41 It is difficult to obtain the coupling relationship between the abovementioned factors and the bed temperature, bed pressure, and pollutant concentration in flue gas through simple tests. Therefore, it was important means to obtain the qualitative and quantitative effects of parameter disturbance on system output through numerical simulation.…”
Section: Resultsmentioning
confidence: 99%