Modeling and control of a multi-phase induction machine with structural unbalance

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
61
0
1

Year Published

2001
2001
2024
2024

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 165 publications
(62 citation statements)
references
References 7 publications
0
61
0
1
Order By: Relevance
“…To ensure current sharing and low current harmonics, Oguchi presented a novel six-phase inverter system in which 60-step output voltages were generated [15] . Several authors have addressed the issue of fault tolerance, focusing for the large part on the behavior and compensation strategies of machines in which a single phase is open circuited and on for opencircuit faults [16][17][18] .…”
Section: Introductionmentioning
confidence: 99%
“…To ensure current sharing and low current harmonics, Oguchi presented a novel six-phase inverter system in which 60-step output voltages were generated [15] . Several authors have addressed the issue of fault tolerance, focusing for the large part on the behavior and compensation strategies of machines in which a single phase is open circuited and on for opencircuit faults [16][17][18] .…”
Section: Introductionmentioning
confidence: 99%
“…is the inductance matrix relating rotor linked fluxes to the stator currents in the first winding; 8) is the inductance matrix relating rotor linked fluxes to the stator currents in the second winding; 9) is the inductance matrix relating rotor linked fluxes to the rotor currents. The submatrices along the main diagonal are symmetrical; the others are circular, and the one describing the stator to rotor coupling depends on the mutual position.…”
Section: )mentioning
confidence: 99%
“…A more theoretical analysis has been conducted in [8], where an original modulation strategy is proposed as a solution to limit the current ripple, and in [9] where the problem is solved by operating directly on the machine structure.…”
Section: Introductionmentioning
confidence: 99%
“…Modeling and control of induction machines in faulty situations have been topic of many studies [1][2][3][4][5]. Zhao and Lipo have carried out research on faulty multi-phase IM where one of the stator phase is cut off [1]. Abbaszadeh et al presented a method for modeling and control of dual 3-phase IM when two stator phase are cutoff [2].…”
Section: Introductionmentioning
confidence: 99%
“…Additionally, modeling and control of faulty or unbalanced IM can be extended to single-phase IM vector control since single-phase IM with different main and auxiliary windings is an unbalanced IM. Modeling and control of induction machines in faulty situations have been topic of many studies [1][2][3][4][5]. Zhao and Lipo have carried out research on faulty multi-phase IM where one of the stator phase is cut off [1].…”
Section: Introductionmentioning