2011
DOI: 10.1109/tpel.2010.2091286
|View full text |Cite
|
Sign up to set email alerts
|

Modeling and Analysis of Grid Harmonic Distortion Impact of Aggregated DG Inverters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
102
0
3

Year Published

2013
2013
2023
2023

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 249 publications
(106 citation statements)
references
References 21 publications
1
102
0
3
Order By: Relevance
“…Finally, the harmonic effects on the asymptotic stability of the computed periodic solutions are analyzed. All case studies presented in the following sections are focused on the switching harmonics caused by the PWM inverters considering the nonlinear and cross-coupling interaction with the DG units, controllers and network elements and components; however, another harmonic sources, such as the background harmonics [13], [34], can be easily taken into account using the proposed fast-time domain methods. A.…”
Section: Fast-time Domain Harmonic Assessmentmentioning
confidence: 99%
See 2 more Smart Citations
“…Finally, the harmonic effects on the asymptotic stability of the computed periodic solutions are analyzed. All case studies presented in the following sections are focused on the switching harmonics caused by the PWM inverters considering the nonlinear and cross-coupling interaction with the DG units, controllers and network elements and components; however, another harmonic sources, such as the background harmonics [13], [34], can be easily taken into account using the proposed fast-time domain methods. A.…”
Section: Fast-time Domain Harmonic Assessmentmentioning
confidence: 99%
“…In addition, previous contributions have exposed that harmonic interactions phenomena arise in controlled microgrids; however, they have not been still fully explored and understood [1], [9], [13], [37]. Therefore, the inherent harmonic cross-coupling, the resonances of the system and the interaction among the network, the control and the power electronic devices, lead to the apparition of non-characteristic harmonic components which are supposed to not exist.…”
Section: Fast-time Domain Harmonic Assessmentmentioning
confidence: 99%
See 1 more Smart Citation
“…The resonant problem of multi-parallel inverters is complex [76,77], and there exists both a fixed and an unfixed resonant band. The fixed resonant band is caused by inverter filter system, and its resonant frequencies will not migrate with the different number of parallel inverters.…”
Section: Harmonic Analysis and Suppression In The Microgrids Operatinmentioning
confidence: 99%
“…In addition, proportional resonant (PR) controllers can realize zero steady-state errors due to their infinite gain at the selected frequency [14]. In this paper a quasi-resonant-proportional current controller is used in the system and it can be defined as: The difference between an LCL filter and a single L filter mainly reflected the attenuation of the high-frequency harmonics.…”
Section: B Control Of Grid-connected Currentmentioning
confidence: 99%