2013
DOI: 10.1109/tie.2012.2194951
|View full text |Cite
|
Sign up to set email alerts
|

Modeling, Analysis, and Design of Stationary-Reference-Frame Droop-Controlled Parallel Three-Phase Voltage Source Inverters

Abstract: Modeling, analysis, and design of stationary reference frame droop controlled parallel three-phase voltage source inverters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
261
0
8

Year Published

2015
2015
2024
2024

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 593 publications
(282 citation statements)
references
References 22 publications
0
261
0
8
Order By: Relevance
“…In addition, a feedforward loop is included in order to take the small variations of dc link voltage (V dc ) into account. Details about droop controllers and voltage/current loops can be found in [9] and [11].…”
Section: Proposed Control Structurementioning
confidence: 99%
See 2 more Smart Citations
“…In addition, a feedforward loop is included in order to take the small variations of dc link voltage (V dc ) into account. Details about droop controllers and voltage/current loops can be found in [9] and [11].…”
Section: Proposed Control Structurementioning
confidence: 99%
“…2 is to enhance the performance of droop controllers and to make the system more damped [6], [11]. The resistive part of resistivecapacitive sub-blocks can be included to improve the sharing of fundamental negative sequence and harmonic components of load current among inverters.…”
Section: B Adaptive Virtual Impedance Schemementioning
confidence: 99%
See 1 more Smart Citation
“…Because the outputs of the PV and the battery are limited, it is not allowed that all ac and dc loads are connected. Fortunately, most residential electric appliances are re-schedulable [6].…”
Section: Fig1 Bess Structurementioning
confidence: 99%
“…The inverter-interfaced DGs have much smaller inertia than a synchronous generator in traditional ac grid and the RES are intermittent, which makes the frequency of an islanded MG at the risk of instability. The droop control methods, which increase virtual inertia of inverter-interfaced DGs by mimicking the governor of a synchronous generator, are widely used as the primary control [2,[4][5][6][7] of an MG. The variability of renewable power sources are compensated by droop-controlled DGs or super capacitor storage systems.…”
Section: Introductionmentioning
confidence: 99%