2008
DOI: 10.1111/j.1440-1746.2008.05421.x
|View full text |Cite
|
Sign up to set email alerts
|

Model consisting of ultrasonographic and simple blood indexes accurately identify compensated hepatitis B cirrhosis

Abstract: Oligonucleotide microarray of the PCR product permits a rapid and accurate screening of SNPs of 23S rRNA gene from H. pylori. It is now possible to apply this hybridization technology in clinical diagnosis and treatment.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
18
0

Year Published

2010
2010
2023
2023

Publication Types

Select...
10

Relationship

1
9

Authors

Journals

citations
Cited by 24 publications
(18 citation statements)
references
References 29 publications
0
18
0
Order By: Relevance
“…2.2 Platelet count of less than 100,000/mm3 excluding the other possible causes. 2.3 Serum albumin less than 3.5 g/dL, or prothrombin time (PT) prolonged or international normalized ratios (INR) > 1.3 (anticoagulants or thrombolytic drugs discontinued more than 7 days) [27, 28]. For pre-cirrhotic CLD cases, the CLD patients who fulfilled the above criteria for clinically diagnosis of cirrhosis were excluded.…”
Section: Methodsmentioning
confidence: 99%
“…2.2 Platelet count of less than 100,000/mm3 excluding the other possible causes. 2.3 Serum albumin less than 3.5 g/dL, or prothrombin time (PT) prolonged or international normalized ratios (INR) > 1.3 (anticoagulants or thrombolytic drugs discontinued more than 7 days) [27, 28]. For pre-cirrhotic CLD cases, the CLD patients who fulfilled the above criteria for clinically diagnosis of cirrhosis were excluded.…”
Section: Methodsmentioning
confidence: 99%
“…On the other hand, patients with persistently normal serum ALT levels may not accept to undergo liver biopsy even though such patients are at risk of progressing to advanced fibrosis or cirrhosis [4]. Sampling error and interobserver variability also hinder liver biopsy from being applied more widely [5].…”
Section: Introductionmentioning
confidence: 99%
“…These included hematology profile, alanine aminotransferase (ALT, normal range 0-40 IU/L), aspartate aminotransferase (AST, normal range 0-45 IU/L), albumin, bilirubin and prothrombin time. 19 Transient elastography scanning TE was performed by two operators (Q.Z. 8,11,15 Ultrasonography Ultrasonic examination and TE were performed on the same day after overnight fasting.…”
Section: Routine Laboratory Testsmentioning
confidence: 99%