2015
DOI: 10.1007/978-3-662-47200-2_11
|View full text |Cite
|
Sign up to set email alerts
|

Model Based Design of Finger Exoskeleton for Post Stroke Rehabilitation Using a Slotted Link Cam with Lead Screw Mechanism

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
4
1
1

Relationship

3
3

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 5 publications
0
3
0
Order By: Relevance
“…Furthermore, even in clinical practice, especially to assess the patients with motor function disorder, the working distance and movement pattern is studied to observe the improvement of motor function recovery. The inspection procedure not only considers one aspect or point of view but the standard protocol of the evaluation also considers multidimensional aspects such as the progress of the motor function recovery, the mechanism of recovery, the body change to the paralyzed side of the patients and other aspects related to the patient's condition which are quantitatively analyzed [20]- [22]. Therefore, the evaluation method of the sanding movement training assessed in our novel measurement system suggests that obtaining motion distance and motion speed, which objectively evaluate the exercise capacity and the range of motion during the training session is effective.…”
Section: Discussionmentioning
confidence: 99%
“…Furthermore, even in clinical practice, especially to assess the patients with motor function disorder, the working distance and movement pattern is studied to observe the improvement of motor function recovery. The inspection procedure not only considers one aspect or point of view but the standard protocol of the evaluation also considers multidimensional aspects such as the progress of the motor function recovery, the mechanism of recovery, the body change to the paralyzed side of the patients and other aspects related to the patient's condition which are quantitatively analyzed [20]- [22]. Therefore, the evaluation method of the sanding movement training assessed in our novel measurement system suggests that obtaining motion distance and motion speed, which objectively evaluate the exercise capacity and the range of motion during the training session is effective.…”
Section: Discussionmentioning
confidence: 99%
“…In the proof of concept study conducted by therapists and healthy subjects [10], it was found that the proposed device actuated with the patient-driven approach could be beneficial for hand rehabilitation. Our proposed device [11] has several limitations. It is needed to adopt adaptive control strategies for each patient's capabilities.…”
Section: Discussionmentioning
confidence: 99%
“…One of the methods in resolving such finger deformities is through performing the motor recovery treatments as suggested in Brunnstrom stages [6], [7]. The physical therapy is dependent on the usage of the muscle strength of the paretic limb which is often under the care of a physiotherapist.…”
Section: Introductionmentioning
confidence: 99%