2015
DOI: 10.1002/col.21962
|View full text |Cite
|
Sign up to set email alerts
|

Model‐based corrections of geometric errors in multiangle measurements of gonio‐apparent coatings

Abstract: Numerical corrections of colorimetric errors caused by positioning error and irregular geometry in multiangle measurements of gonio-apparent coatings are presented. These corrections use a model function approximating the gonio-reflection characteristics of the coating to convert the angular displacement due to those geometric errors to reflectance factor errors to be corrected as well as to estimate the angular displacement conversely from the reflectance factors. The performance of these corrections was eval… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2018
2018
2018
2018

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 7 publications
0
2
0
Order By: Relevance
“…This instrument is characterized by a new lateral double illumination system at 45° for minimizing colorimetric errors caused by positioning error in multiangle measurements with an area of measurement of 12 mm. A possible irregular geometry of its optics has been corrected . Therefore, the main purpose of this study is to evaluate the instrumental inter‐model‐agreement of the spectral and colorimetric data of the new multiangle spectrophotometer from Konica Minolta with regard to other current commercial multiangle spectrophotometers available in the market in order to guarantee good performance between instruments.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…This instrument is characterized by a new lateral double illumination system at 45° for minimizing colorimetric errors caused by positioning error in multiangle measurements with an area of measurement of 12 mm. A possible irregular geometry of its optics has been corrected . Therefore, the main purpose of this study is to evaluate the instrumental inter‐model‐agreement of the spectral and colorimetric data of the new multiangle spectrophotometer from Konica Minolta with regard to other current commercial multiangle spectrophotometers available in the market in order to guarantee good performance between instruments.…”
Section: Introductionmentioning
confidence: 99%
“…A possible irregular geometry of its optics has been corrected. 34 Therefore, the main purpose of this study is to evaluate the instrumental inter-model-agreement of the spectral and colorimetric data of the new multiangle spectrophotometer from Konica Minolta with regard to other current commercial multiangle spectrophotometers available in the market in order to guarantee good performance between instruments.…”
Section: Introductionmentioning
confidence: 99%