2015
DOI: 10.1016/j.apradiso.2015.07.037
|View full text |Cite
|
Sign up to set email alerts
|

Mock-up experiment at Birmingham University for BNCT project of Osaka University – Neutron flux measurement with gold foil

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 2 publications
0
4
0
Order By: Relevance
“…The neutron moderator assembly used in the 1mA test was designed basing on various experiences of neutronic experiments at OKTAVIAN neutron source facility, and consisted of planer Li layer surrounded by cylindrical graphite reflector and dual component moderator of 20cm in diam. The detailed configuration and results are shown in papers [5][6][7]. The data report neutron flux and -ray distribution on the bottom surface of the assembly, that is, on the patient-side surface of the wall.…”
Section: Neutron Moderator Assemblymentioning
confidence: 99%
“…The neutron moderator assembly used in the 1mA test was designed basing on various experiences of neutronic experiments at OKTAVIAN neutron source facility, and consisted of planer Li layer surrounded by cylindrical graphite reflector and dual component moderator of 20cm in diam. The detailed configuration and results are shown in papers [5][6][7]. The data report neutron flux and -ray distribution on the bottom surface of the assembly, that is, on the patient-side surface of the wall.…”
Section: Neutron Moderator Assemblymentioning
confidence: 99%
“…The most common method is the use of a gold wire. Here, the gold wire is set in water and then the radioactivity of the wires is measured with a radiation detector, such as a semiconductor detector, after irradiation of the neutron beam [3]. Since this is a reliable method to determine the neutron distribution, it is now the most commonly used method for QA of neutron beams in BNCT facilities.…”
Section: Introductionmentioning
confidence: 99%
“…One method is to position gold foil wires at different depths in water and then measure the radioactivity of the foil after irradiation of neutrons to estimate the thermal neutron distribution. 3 This is a reliable method to determine the thermal neutron distribution, but the need to measure radioactivity in gold is timeand labor-consuming. Another method adopts an optical fiber-based detector using a neutron-sensitive scintillator to measure the thermal neutron distribution.…”
Section: Introductionmentioning
confidence: 99%
“…However, it is difficult to measure the dose distribution in water. One method is to position gold foil wires at different depths in water and then measure the radioactivity of the foil after irradiation of neutrons to estimate the thermal neutron distribution 3 . This is a reliable method to determine the thermal neutron distribution, but the need to measure radioactivity in gold is time‐ and labor‐consuming.…”
Section: Introductionmentioning
confidence: 99%