Mock Circulatory Loop Compliance Chamber Employing a Novel Real-Time Control Process

Abstract: The use of compliance chambers in mock circulatory loop construction is the predominant means of simulating arterial compliance. Utilizing mock circulatory loops as bench test methods for cardiac assist technologies necessitates that they must be capable of reproducing the circulatory conditions that would exist physiologically. Of particular interest is the ability to determine instantaneous compliance of the system, and the ability to change the compliance in real-time. This capability enables continuous bat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(9 citation statements)
references
References 10 publications
(12 reference statements)
0
9
0
Order By: Relevance
“…The compliance chamber allowed us to simulate the arterial compliance and to obtain physiologic diastolic pressures and pressure waveforms. The compliance chamber provides the capacitance of the circulatory system, which is crucial for maintaining the blood pressure during ventricular diastole and dampening pressure waves . The compliance chamber was placed in the DAo in order to avoid the damping of the inflow velocities and to simulate the arterial compliance downstream from the phantom …”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The compliance chamber allowed us to simulate the arterial compliance and to obtain physiologic diastolic pressures and pressure waveforms. The compliance chamber provides the capacitance of the circulatory system, which is crucial for maintaining the blood pressure during ventricular diastole and dampening pressure waves . The compliance chamber was placed in the DAo in order to avoid the damping of the inflow velocities and to simulate the arterial compliance downstream from the phantom …”
Section: Discussionmentioning
confidence: 99%
“…A compliance chamber (Fig. A) was installed in the circuit after the DAo in order to simulate arterial compliance, to obtain physiologic diastolic pressures and physiologic pressure waveforms. It was built using transparent acrylic of 4 mm thick with a total internal volume of 600 cm 3 .…”
Section: Methodsmentioning
confidence: 99%
“…Mock circulatory loops (MCL) were developed to test cardiovascular devices in vitro by recreating physiological pulsatile blood flow conditions [10][11][12]. The principal components of closed-loop MCL are as follows: (i) the pulsatile pump, (ii) the expansion chamber with an air cushion to replicate the Windkessel effect of the arterial tree, and (iii) pinch valves to reproduce the peripheral resistance.…”
Section: Introductionmentioning
confidence: 99%
“…For future MCLs, it is imperative to address these limitations of current MCLs. Integrating fully automated compliance chambers 138 and resistance devices 139 allows the implementation of the necessary autoregulation of the CVS. Parts of the CVS that are too difficult to model hydraulically can be implemented into the MCL with a numerical model, obtaining a flexible and cost-effective H-MCL.…”
Section: Discussionmentioning
confidence: 99%