δ13C signatures of organic aerosols: Measurement method evaluation and application in a source study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
13
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
6
2

Relationship

3
5

Authors

Journals

citations
Cited by 15 publications
(14 citation statements)
references
References 38 publications
1
13
0
Order By: Relevance
“…The OC EF was inversely proportional to the MCE (Liu et al, 2014b;Pokhrel et al, 2016;Yokelson et al, 1997), meaning OC is predominantly emitted during RSC. For the prescribed fires, we found less volatile OC to be more depleted than more volatile OC, which is more often the case for BB burning (Yao et al, 2022;Zenker et al, 2020). The conversion EC was relatively stable, though 13 C-depleted with average fractionation of -2.2  2.3‰, which was similar in FC and RSC emissions.…”
Section: Carbon Fractionation In Different Reaction Productssupporting
confidence: 53%
See 1 more Smart Citation
“…The OC EF was inversely proportional to the MCE (Liu et al, 2014b;Pokhrel et al, 2016;Yokelson et al, 1997), meaning OC is predominantly emitted during RSC. For the prescribed fires, we found less volatile OC to be more depleted than more volatile OC, which is more often the case for BB burning (Yao et al, 2022;Zenker et al, 2020). The conversion EC was relatively stable, though 13 C-depleted with average fractionation of -2.2  2.3‰, which was similar in FC and RSC emissions.…”
Section: Carbon Fractionation In Different Reaction Productssupporting
confidence: 53%
“…OC and EC quantities on the filter samples were determined using a thermal-optical analyser (Sunset Laboratory Inc.), according to the EUSAAR-2 protocol. The measurement setup and measurement protocol for stable carbon isotopes of OC and EC are described in detail by Yao et al (2021) and Zenker et al (2020). To stay within the systems' measurement range of 2-24 g C, small segments of 0.13 to 3.00 cm 2 were punched from the filter samples.…”
Section: Aerosol Sampling and Analysismentioning
confidence: 99%
“…The OC EF was inversely proportional to the MCE (S. Pokhrel et al, 2016;Yokelson et al, 1997), meaning OC is predominantly emitted during RSC. For the prescribed fires, we found less volatile OC to be more depleted than more volatile OC, which is more often the case for BB (Yao et al, 2022;Zenker et al, 2020). The conversion to EC was relatively stable, though 13 C-depleted with average fractionation of −2.2 ± 2.3 ‰, which was similar in FC and RSC emissions.…”
Section: Carbon Fractionation In Different Reaction Productsmentioning
confidence: 57%
“…OC and EC quantities on the filter samples were determined using a thermal-optical analyser (Sunset Laboratory Inc), according to the EUSAAR-2 protocol. The measurement set-up and measurement protocol for stable carbon isotopes of OC and EC are described in detail by Yao et al (2022) and Zenker et al (2020). To stay within the systems' measurement range of 2-24 µg C, small segments of 0.13 to 3.00 cm 2 were punched from the filter samples.…”
Section: Aerosol Sampling and Analysismentioning
confidence: 99%
“…The distinction between OC and EC was based on the EUSAAR_2 protocol (Cavalli and Putaud, 2008) using the transmittance of a laser beam (λ = 630 nm) through the filter to determine the relative contribution of OC and EC of the measured filter (Bauer et al, 2009). The measurement setup and measurement protocol are described in detail by Zenker et al (2020).…”
Section: Ec/oc Analysis Using Sunset Analysermentioning
confidence: 99%