2018
DOI: 10.1109/tthz.2018.2871365
|View full text |Cite
|
Sign up to set email alerts
|

MKID Large Format Array Testbed

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
7
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
5
1

Relationship

4
2

Authors

Journals

citations
Cited by 6 publications
(10 citation statements)
references
References 18 publications
2
7
0
Order By: Relevance
“…In Fig. 4a, we give NEP exp (P abs , f = 200 Hz) together with the theoretical value of the photon noise background from the radiation source and obtain a result very similar to those of de Visser et al 18 ,Baselmans et al 12 and Ferrari et al 36 , but with ten times greater sensitivity. For a comparison of the NEP as a function of the absorbed power as shown in Fig.…”
Section: Methodssupporting
confidence: 78%
See 2 more Smart Citations
“…In Fig. 4a, we give NEP exp (P abs , f = 200 Hz) together with the theoretical value of the photon noise background from the radiation source and obtain a result very similar to those of de Visser et al 18 ,Baselmans et al 12 and Ferrari et al 36 , but with ten times greater sensitivity. For a comparison of the NEP as a function of the absorbed power as shown in Fig.…”
Section: Methodssupporting
confidence: 78%
“…where P is the radiation power, given now by P s , which is the power from the source that can couple to a single mode. P s is calculated from the radiator temperature and the measured filter transmission using the formalism explained in detail in Appendix B of Ferrari et al 36 . Figure 3a shows the phase noise power spectral density S θ ( f ) for one representative device, which has a resonance frequency of 2.74 GHz and an aluminium length of 913 µm.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…In this paper we only summarize the experimental setup for this measurement, but it is covered in detail in Davis et al 12 . As an example for the analysis we use data from a lab based reflective optics based large field camera with a base T of 240 mK, see Ferrari et al 13 for more details. An overview of the optics is shown in Fig.…”
Section: Experimental Methodsmentioning
confidence: 99%
“…GRASP simulations of the full end-to-end optical system predict a waist size of ≈ 3.25 mm in this focal plane [27]. More details on the cryostat and optics system are presented in [25] and [28].…”
Section: A Test Arraymentioning