2015
DOI: 10.1016/j.soildyn.2015.09.005
|View full text |Cite
|
Sign up to set email alerts
|

Mitigation of railway-induced vibration by using subgrade stiffening

Abstract: Railway-induced ground vibration is often associated with sites with soft ground. Stiffening of the subgrade beneath the railway track is one particular measure that has potential to reduce the vibration level at such sites. However, the mechanisms behind this reduction are not well understood. Here, the effects are examined in the context of two alternative approaches: (i) subgrade stiffening, where the soil directly under the track is stiffened, and (ii) stiff inclusions introduced at some depth beneath the … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
28
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 59 publications
(28 citation statements)
references
References 22 publications
0
28
0
Order By: Relevance
“…This frequency (20 Hz here) will be referred to in the remainder of the paper as the 'cut-on' frequency of the upper layer. For the deeper surface layer, not shown here, the same phenomena occur but at lower frequencies, with the first surface wave becoming localised in the upper layer from around 10 Hz [7]. vibration by using subgrade stiffening 89-103, with permission from Elsevier) [7].…”
Section: Dispersion and Response To Unit Loadsmentioning
confidence: 54%
See 4 more Smart Citations
“…This frequency (20 Hz here) will be referred to in the remainder of the paper as the 'cut-on' frequency of the upper layer. For the deeper surface layer, not shown here, the same phenomena occur but at lower frequencies, with the first surface wave becoming localised in the upper layer from around 10 Hz [7]. vibration by using subgrade stiffening 89-103, with permission from Elsevier) [7].…”
Section: Dispersion and Response To Unit Loadsmentioning
confidence: 54%
“…The same ground parameters were considered in [7] to study the effect of subgrade stiffening. These properties are typical of sites investigated during the EU FP7 project RIVAS (Railway Induced Vibration Abatement Solutions) [53] and are based loosely on sites identified at Rubigen in Switzerland where an upper layer of silty sand with clay and gravel, with a thickness of 2-10 m, is located over a stiffer substratum of silty gravel with sand.…”
Section: Ground Propertiesmentioning
confidence: 99%
See 3 more Smart Citations