2010
DOI: 10.1016/j.epsr.2009.12.001
|View full text |Cite
|
Sign up to set email alerts
|

Minimization of shaft oscillations by fuzzy controlled SMES considering time delay

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
8
0

Year Published

2012
2012
2020
2020

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 10 publications
(8 citation statements)
references
References 33 publications
0
8
0
Order By: Relevance
“…In this work, the effect of SVC or SC on minimizing the torsional oscillations is evaluated by using the index, TOR (pu s) given as follows: TOR=true0tsim||ΔTorquedt0.25em()pu0.25ems where ΔTorque is the torsional oscillations in Gen‐LP and LP‐HP sections and t sim is the simulation time. A better performance of devices is verified by the lower values of TOR index.…”
Section: Simulations and Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…In this work, the effect of SVC or SC on minimizing the torsional oscillations is evaluated by using the index, TOR (pu s) given as follows: TOR=true0tsim||ΔTorquedt0.25em()pu0.25ems where ΔTorque is the torsional oscillations in Gen‐LP and LP‐HP sections and t sim is the simulation time. A better performance of devices is verified by the lower values of TOR index.…”
Section: Simulations and Discussionmentioning
confidence: 99%
“…As seen in Figure , the time delay is described by e −τs in this paper. The value of the time delay ( τ ) has been discussed in . The range of time delay usually varies from several microseconds to few hundred milliseconds.…”
Section: Supplementary Subsynchronous Damping Controller (Ssdc)mentioning
confidence: 99%
“…The presented method in Ali et al. 11 analyzed the effect of fuzzy logic-controlled super-conductive magnetic energy storage (SMES) on minimizing shaft torsional oscillations of synchronous generators in a multi-machine power system. In the aforementioned paper, considering only one input variable and one output variable, the proposed fuzzy logic controller has been designed.…”
Section: Introductionmentioning
confidence: 99%
“…Transient faults in a power system lead to a shaft torsional oscillation of synchronous generators . Therefore, the effect of fuzzy logic‐controlled SMES on minimizing shaft torsional oscillations of the generators in a multi‐machine power system was analyzed.…”
Section: Introductionmentioning
confidence: 99%
“…Transient faults in a power system lead to a shaft torsional oscillation of synchronous generators. 16 Therefore, the effect of fuzzy logic-controlled SMES on minimizing shaft torsional oscillations of the generators in a multi-machine power system was analyzed. Ngamroo 17 proposed an optimization technique to adjust the power controller parameters and coil size of multiple SMES units in interconnected power systems with wind farms.…”
mentioning
confidence: 99%