2011
DOI: 10.1002/ccd.23354
|View full text |Cite
|
Sign up to set email alerts
|

Minimally invasive insertion of an equine stented pulmonary valve with a built‐in sinus portion in a sheep model

Abstract: The newly developed hydraulic release system allowed for safe and reliable insertion of an equine stented-valve with a sinus portion, through a right transventricular approach on a beating heart, in a sheep survival model.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 11 publications
0
3
0
Order By: Relevance
“…The original search by Uiterwijk et al 20 identified 817 articles, of which 80 were included in qualitative analysis for this study, after reassessment of studies that reported on additional data from previously reported animals ( Supplemental Figure 1 ). All 80 studies 37 , 39 , 40 , 41 , 42 , 44 , 45 , 46 , 47 , 48 , 49 , 50 , 51 , 52 , 53 , 54 , 55 , 56 , 57 , 58 , 59 , 60 , 61 , 62 , 63 , 64 , 65 , 66 , 67 , 68 , 69 , 70 , 71 , 72 , 73 , 74 , 75 , 76 , 77 , 78 , 79 , 80 , 81 , 82 , 83 , 84 , 85 , 86 , 87 , 88 , 89 , 90 , 91 , 92 , 93 , 94 , 95 , 96 , 97 , 98 , 99 , 100 , 101 ,…”
Section: Resultsmentioning
confidence: 99%
“…The original search by Uiterwijk et al 20 identified 817 articles, of which 80 were included in qualitative analysis for this study, after reassessment of studies that reported on additional data from previously reported animals ( Supplemental Figure 1 ). All 80 studies 37 , 39 , 40 , 41 , 42 , 44 , 45 , 46 , 47 , 48 , 49 , 50 , 51 , 52 , 53 , 54 , 55 , 56 , 57 , 58 , 59 , 60 , 61 , 62 , 63 , 64 , 65 , 66 , 67 , 68 , 69 , 70 , 71 , 72 , 73 , 74 , 75 , 76 , 77 , 78 , 79 , 80 , 81 , 82 , 83 , 84 , 85 , 86 , 87 , 88 , 89 , 90 , 91 , 92 , 93 , 94 , 95 , 96 , 97 , 98 , 99 , 100 , 101 ,…”
Section: Resultsmentioning
confidence: 99%
“…So far, only two studies have reported the implementation of Valsalva sinuses into TEHVs. 20,62 Dodge–Khatami and colleagues 62 used decellularized equine valved jugular veins as TPVR in sheep, showing promising functionality and endothelialization potential. However, the use of non-fixed xenogeneic material may represent a significant limitation for their future clinical translation.…”
Section: Discussionmentioning
confidence: 99%
“…However, surgically augmented RVOTs can vary considerably in their geometry and dimensions [53], and undergo complex and sometimes extreme deformation during the cardiac cycle [54], which can present a unique set of challenges when it comes to developing devices that are feasible and effective for a wide population of patients. Early preclinical experience with other TPV devices, some designed for large outflow tracts, has also been described [55][56][57][58][59][60].…”
Section: Expanded Applications and The Future Of Tpv Replacementmentioning
confidence: 99%