2023
DOI: 10.24287/1726-1708-2023-22-3-199-209
|View full text |Cite
|
Sign up to set email alerts
|

Minimal residual disease monitoring in B-lineage acute lymphoblastic leukemia using flow cytometry. Guidelines of the Russian-Belarusian multicenter group for pediatric acute leukemia studies

A. M. Popov,
E. V. Mikhailova,
T. Yu. Verzhbitskaya
et al.

Abstract: Multicolor flow cytometry is now routinely used in laboratory practice for minimal residual disease (MRD) monitoring in B-cell precursor acute lymphoblastic leukemia (BCP-ALL). This article describes the methodology of MRD detection in BCP-ALL using flow cytometry as recommended by the Russian-Belarusian multicenter group for pediatric acute leukemia studies. This wellharmonized approach includes recommendations for the choice of monoclonal antibodies, sample preparation, cytometer setup, flow cytometry data a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4

Relationship

4
0

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 37 publications
(33 reference statements)
0
2
0
Order By: Relevance
“…Based on the cytogenetic data, patients were classified into low (high hyperdiploidy (HeH) and translocation t(12;21)(p13;q22)/ ETV6 :: RUNX1 13 ) and intermediate (all others) cytogenetic risk groups 13 . MRD was evaluated using a 6–9 color MFC in three laboratories using a well‐harmonized approach 15,16 . All laboratories use the same MFC methodology based on standard analyzes and had participated in the AIEOP‐BFM‐QA system 17 and group‐internal proficiency tests 15 .…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Based on the cytogenetic data, patients were classified into low (high hyperdiploidy (HeH) and translocation t(12;21)(p13;q22)/ ETV6 :: RUNX1 13 ) and intermediate (all others) cytogenetic risk groups 13 . MRD was evaluated using a 6–9 color MFC in three laboratories using a well‐harmonized approach 15,16 . All laboratories use the same MFC methodology based on standard analyzes and had participated in the AIEOP‐BFM‐QA system 17 and group‐internal proficiency tests 15 .…”
Section: Methodsmentioning
confidence: 99%
“… 13 MRD was evaluated using a 6–9 color MFC in three laboratories using a well‐harmonized approach. 15 , 16 All laboratories use the same MFC methodology based on standard analyzes and had participated in the AIEOP‐BFM‐QA system 17 and group‐internal proficiency tests. 15 MRD negativity was defined as <0.01%.…”
Section: Methodsmentioning
confidence: 99%