2004
DOI: 10.1002/jms.768
|View full text |Cite
|
Sign up to set email alerts
|

Miniaturized system of a gas chromatograph coupled with a Paul ion trap mass spectrometer

Abstract: On page 38, line 20, units of is printed as (rad)15 1, it should have been printed as (rad s 1. On page 39, line 51, the text was incorrectly printed as follows: 'This leads to an avoidable acceleration of the electron beam, and to a different ionisation impact cross-section (and branching fractions) than encountered for the case of the NIST tabulation at the standard 70 eV ionisation energy' The text should have been printed as: 'This leads to an unavoidable acceleration of the electron beam, and to a differe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
33
0

Year Published

2005
2005
2019
2019

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 49 publications
(33 citation statements)
references
References 14 publications
(14 reference statements)
0
33
0
Order By: Relevance
“…The JPL team has continuously improved and miniaturized a mass spectrometer, recently adding GC and preconcentrator capabilities to the front end 94 with good performance for most of the listed compounds:…”
Section: Vcam Development Unitmentioning
confidence: 99%
“…The JPL team has continuously improved and miniaturized a mass spectrometer, recently adding GC and preconcentrator capabilities to the front end 94 with good performance for most of the listed compounds:…”
Section: Vcam Development Unitmentioning
confidence: 99%
“…[19-24] The advantages of ion trap analyzers include their small size, relatively high operating pressure and the MS/MS capability. Currently, several portable miniature MS instruments have been developed using ion trap mass analyzers, including as the Mini10,[25] Mini 11,[26] and Mini12[27] from Purdue University, Tridion-9 GC-MS[28] from Torion Inc. (American Fork, UT), GC/QIT[29] from the Jet Propulsion Laboratory, Chemsense 600[30] from Griffin Analytical Technology LLC. (West Lafayette, IN), and the MMS-1000 from 1 st Detect Inc. (Austin, TX).…”
Section: Introductionmentioning
confidence: 99%
“…Applications include monitoring public safety areas [1], detecting chemical warfare agents (CWA) in battlefield situations [2,3], analyzing harsh environmental conditions [4,5], ensuring industrial quality control [6], and even screening in medicine [7]. One of the shortcomings for in situ analysis is sample collection, extraction, separation, or other special treatments that are needed for certain samples [8].…”
Section: Introductionmentioning
confidence: 99%
“…For instance, there has been much effort recently in coupling scaled-down gas chromatographs (GC) with portable MS systems [2,3,9,10]. These GC systems have been made more field-portable, and the resulting analysis times have been significantly reduced.…”
Section: Introductionmentioning
confidence: 99%