2019
DOI: 10.1007/s12127-019-00248-w
|View full text |Cite
|
Sign up to set email alerts
|

Miniaturized high-performance drift tube ion mobility spectrometer

Abstract: Developing powerful hand-held drift tube ion mobility spectrometers (IMS) requires small, lightweight drift tubes with high analytical performance. In this work, we present an easy-to-manufacture, miniaturized drift tube ion mobility spectrometer, which is manufactured from polyether ether ketone, stainless steel foils and printed circuit boards. It is possible to operate the drift tube IMS with a radioactive 3 H ionization source or a non-radioactive X-ray ionization source with 3 kVacceleration voltage. The … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
36
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 30 publications
(37 citation statements)
references
References 14 publications
1
36
0
Order By: Relevance
“…Retention times, reduced ion mobilities and detection limits of all investigated substances are listed in Table 2. Regarding the differences in detection limits when comparing stand-alone IMS [24] and GC-IMS, the following aspects should be kept in mind besides dilution effects due to peak broadening. Dilution effects in fittings and in the IMS reaction region, although the reaction region was kept at a minimum.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…Retention times, reduced ion mobilities and detection limits of all investigated substances are listed in Table 2. Regarding the differences in detection limits when comparing stand-alone IMS [24] and GC-IMS, the following aspects should be kept in mind besides dilution effects due to peak broadening. Dilution effects in fittings and in the IMS reaction region, although the reaction region was kept at a minimum.…”
Section: Resultsmentioning
confidence: 99%
“…The volume of the reaction region of the IMS is just 160 μL keeping the GC resolving power. The IMS used in this work has been basically described elsewhere [24]. Limits of detection have been determined in the range of ppt v within averaging times of 1 s. Outer overall dimensions are only 15 mm × 15 mm × 56 mm.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…For ionization, a 130 MBq tritium source is used in this work. However, other non-radioactive sources can be easily used [13]. Once the ions are injected in the drift region by a field switching shutter [14], they are moving along the drift tube, driven by an electrical field.…”
Section: Drift Tube Ion Mobility Spectrometermentioning
confidence: 99%