2015
DOI: 10.1016/j.aca.2015.09.015
|View full text |Cite
|
Sign up to set email alerts
|

Miniaturised medium pressure capillary liquid chromatography system with flexible open platform design using off-the-shelf microfluidic components

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
28
0
1

Year Published

2017
2017
2023
2023

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 46 publications
(29 citation statements)
references
References 27 publications
0
28
0
1
Order By: Relevance
“…Encouragingly, this a very active area of research with several very different approaches. Miniature pressure-generating pumps based on piston pumps; syringe pumps; latent energy pumping; and electroosmotic pumps (EOPs) have all been reported [58,[65][66][67]. There are certain features which the ideal portable pumping system should possess: it should be lightweight and batteryoperable; capable of a wide range of flow rates (nL-µL-mL/ min); provide high flow rate accuracy and precision; generate a constant flow rate independent of back pressure; capable of gradient elution with high reproducibility; simple to channel from the inlet to the outlet.…”
Section: The High Pressure Pumpmentioning
confidence: 99%
See 1 more Smart Citation
“…Encouragingly, this a very active area of research with several very different approaches. Miniature pressure-generating pumps based on piston pumps; syringe pumps; latent energy pumping; and electroosmotic pumps (EOPs) have all been reported [58,[65][66][67]. There are certain features which the ideal portable pumping system should possess: it should be lightweight and batteryoperable; capable of a wide range of flow rates (nL-µL-mL/ min); provide high flow rate accuracy and precision; generate a constant flow rate independent of back pressure; capable of gradient elution with high reproducibility; simple to channel from the inlet to the outlet.…”
Section: The High Pressure Pumpmentioning
confidence: 99%
“…The system was reported to achieve high pressures. However, these syringe pumps are not designed for precision flow or high-pressure applications [65] since there is considerable variation between pumps in manufacture and all suffer from pronounced oscillatory flow profiles. These issues are not covered in published accounts.…”
Section: Et Al (2015)mentioning
confidence: 99%
“…Column robustness issues and extra‐column band broadening related to poor connections in capillary systems are reduced through the use of a novel cartridge design that applies appropriate torque for fluidic connections at pressures up to 10 000 psi. This is in contrast to other portable LC systems that employ more traditional LC column integration and lower pressure limits . This first report demonstrating the use of the new, compact LC system addresses several common applications in the pharmaceutical and forensic fields.…”
Section: Introductionmentioning
confidence: 98%
“…[7] был предложен портативный жидкостный хроматограф с электрохимическим детектором, работающий на батареях. Десять лет позднее Г.Барам с сотрудниками [8,9] [16][17][18][19][20][21]. Первые детекторы на светодиодах в красном свете появились в 60-х годах [16], позднее были разработаны в УФ, видимом и инфракрасных (ИК) областях [17].…”
Section: Introductionunclassified