2010
DOI: 10.1016/j.talanta.2010.08.001
|View full text |Cite
|
Sign up to set email alerts
|

Miniature open channel scrubbers for gas collection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
13
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 14 publications
(13 citation statements)
references
References 34 publications
0
13
0
Order By: Relevance
“…Assuming that the PPWD walls and the DS inner tubing are perfect sinks for target gases, the ideal CE of both collectors was estimated by the spreadsheets that Berg et al 19 and Toda et al 20 newly developed. We obtained a theoretical CE of each gas by entering the collectors dimensions (42 cm length and 6.0 cm width in active wall area, 0.30 cm distance between the walls for PPWD, 45 cm length and 0.13 cm outside radius in active tubing, 0.575 cm inside radius in inert tubing for DS) and the gas diffusion coefficients (0.132 cm 2 21,22 in the spreadsheets.…”
Section: Comparison Of Ppwd With the Ds-gas Collection Efficiency-mentioning
confidence: 99%
See 1 more Smart Citation
“…Assuming that the PPWD walls and the DS inner tubing are perfect sinks for target gases, the ideal CE of both collectors was estimated by the spreadsheets that Berg et al 19 and Toda et al 20 newly developed. We obtained a theoretical CE of each gas by entering the collectors dimensions (42 cm length and 6.0 cm width in active wall area, 0.30 cm distance between the walls for PPWD, 45 cm length and 0.13 cm outside radius in active tubing, 0.575 cm inside radius in inert tubing for DS) and the gas diffusion coefficients (0.132 cm 2 21,22 in the spreadsheets.…”
Section: Comparison Of Ppwd With the Ds-gas Collection Efficiency-mentioning
confidence: 99%
“…The gaseous molecules need to diffuse through the pores. Toda et al 20,23 reported that the CE of SO2 and H2S differed significantly between membranes of pPTFE, expanded PTFE, Nafion, porous polypropylene, and silicone. At 0.5 dm 3 min -1 , our experimental SO2 CE of DS was 60.8 ± 2.1%.…”
Section: Comparison Of Ppwd With the Ds-gas Collection Efficiency-mentioning
confidence: 99%
“…Miniature systems based on open channels that do not rely on any membrane structure have also been reported [17,18]. These systems provide an effective way to establish a large gas-liquid interface area and eliminate issues related with membranes.…”
Section: Introductionmentioning
confidence: 99%
“…Ion chromatography (IC) has also proven to be useful for both gas-and particle-phase ammonia and amines (Gibb et al, 1999;Hiranuma et al, 2010;Orsini et al, 2003;Praplan et al, 2012;VandenBoer et al, 2011). Formation of an indophenol complex which is measured spectrometrically has been developed for ammonia (Scheiner, 1976;Solórzano, 1969), as have various techniques involving the formation of 1-sulfonatoisoindole followed by fluorescence measurement (Toda et al, 2010;Zhang et al, 1989). For atmospheric ammonia measurement techniques, several intercomparison studies, in both field and laboratory settings, have been reported in the literature (von Bobrutzki et al, 2010;Fehsenfeld et al, 2002;Kirchner et al, 1999;Norman et al, 2009;Schwab et al, 2007;Wiebe et al, 1990;Williams et al, 1992).…”
Section: Introductionmentioning
confidence: 99%