2002
DOI: 10.1016/s0039-9140(02)00425-3
|View full text |Cite
|
Sign up to set email alerts
|

Miniature flow injection analyser for laboratory, shipboard and in situ monitoring of nitrate in estuarine and coastal waters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
18
0
2

Year Published

2004
2004
2013
2013

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 33 publications
(20 citation statements)
references
References 12 publications
0
18
0
2
Order By: Relevance
“…Gardolinski et al [12] developed a miniaturised, LED-based chemical analyser for in-situ monitoring of nitrate. The limit of detection (LOD) with a 20 mm path length flow cell was 2.8 mg L -1 N. The linear range could be adjusted to suit local conditions in the field by changing the flow cell path length.…”
Section: Examples Of Deployable Microfluidic Devicesmentioning
confidence: 99%
“…Gardolinski et al [12] developed a miniaturised, LED-based chemical analyser for in-situ monitoring of nitrate. The limit of detection (LOD) with a 20 mm path length flow cell was 2.8 mg L -1 N. The linear range could be adjusted to suit local conditions in the field by changing the flow cell path length.…”
Section: Examples Of Deployable Microfluidic Devicesmentioning
confidence: 99%
“…Gardolinski et al [22] reported a solid-state flow-cell detector with 20 mm long path length for in-situ measurements of nitrate. We investigated three different path lengths, 10 mm, 20 mm and 30 mm flow-cell detectors being made out of thick rubber block.…”
Section: Long Path-length Flow Cellmentioning
confidence: 99%
“…The determination of nitrate was achieved by on-line reduction to nitrite with the copperized cadmium column before its reaction with sulfanilamide and NEDA. From previous literature, 9,10 it is prominent that the reduction should be carried out in a neutral or slightly alkaline medium to prevent any further reduction of NO2 -to NO -because of its similar electromotive forces (Eo). For this reason, ammonium chloride is usually employed as the carrier stream.…”
Section: Laboratory Optimizationmentioning
confidence: 99%
“…10 For on-line reduction, the mini column's length in the range of 5 -20 cm long has been employed by previous authors. 9 We have used a column of 2.5 cm length (2 mm i.d.) which was sufficient for quantitative reduction (> 95%), which resulted in minimizing back pressure problems.…”
Section: Laboratory Optimizationmentioning
confidence: 99%
See 1 more Smart Citation