Mini-implantes: pontos consensuais e questionamentos sobre o seu uso clínico

Abstract: Pontos consensuais sobre os mini-imPlantesSobre o uso de mini-implantes na prática ortodôntica como ancoragem esquelética alguns pontos parecem ser consensuais , tais como: 1. Representam uma das principais inovações na prática clínica ortodôntica dos últimos 10 anos, senão a mais relevante da Ortodontia contemporânea.2. A ancoragem oferecida pode ser utilizada logo após a sua implantação ou até 15 dias depois. A quantidade de força inicial deve ser entre 150 e 200g, preferencialmente mensurada com o dinâ-mom… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
11
0
2

Year Published

2012
2012
2017
2017

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 11 publications
(14 citation statements)
references
References 26 publications
(2 reference statements)
1
11
0
2
Order By: Relevance
“…The results showed that SIN and NEO exhibited the highest mean fracture resistance as referred elsewhere 21 . The lower fracture torque on the neck was found in DEN (23.45 N.cm).…”
Section: Discussionsupporting
confidence: 61%
“…The results showed that SIN and NEO exhibited the highest mean fracture resistance as referred elsewhere 21 . The lower fracture torque on the neck was found in DEN (23.45 N.cm).…”
Section: Discussionsupporting
confidence: 61%
“…The preparation of the implant sites and the placement of the prosthetic roots have been carried out following the rules laid down by primary bone reparation. [1][2][3][4][5][6] To define the depth of work, the True Max Implant probe (TMI, Rome, Italy) has been used at a speed lower than 40 revolutions/min without irrigation, so as to not traumatize the alveolar bone. Subsequently, the site has been completed with UNICA osteotome (TMI) at a speed lower than 60 revolutions/min.…”
Section: Discussionmentioning
confidence: 99%
“…3,4 The mechanical imbrication of the mini-implant body to the bone, that is, its primary stability, is critical to the success of the technique. 5 The primary stability of mini-implants can be affected by the screw and the host. Therefore, mini-implant design, bone quality, and insertion technique and angle must be carefully analyzed before installation.…”
Section: Insertion Torque and Pull-out Strength Of Orthodontic Miniimmentioning
confidence: 99%
“…As inflammation recedes over the hours, neighboring cementoblasts and periodontal ligament reserve cells form a new layer of cementoblasts which covers the surface and starts to form a new cementum with reinsertion of periodontal fibers, thus restoring the physiology at the site. 1,4 This cementum might resemble, more or less, the original one and might be occasionally referred to as osteocementum or cementoid tissue.…”
Section: Gliding Without Mineralized Structure Lossmentioning
confidence: 99%