2011
DOI: 10.1016/j.jneumeth.2010.10.015
|View full text |Cite
|
Sign up to set email alerts
|

Mini-coil for magnetic stimulation in the behaving primate

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
23
0

Year Published

2012
2012
2021
2021

Publication Types

Select...
5
3
1

Relationship

0
9

Authors

Journals

citations
Cited by 32 publications
(24 citation statements)
references
References 33 publications
1
23
0
Order By: Relevance
“…Simulation models of 50 TMS coil configurations: (1) Animal mini-coil, 145 (2) Magstim 50 mm circular coil (P/N 9999), 146 (3) 50 mm circular coil with iron core, 70 (4) Magstim 70 mm circular coil (P/N 3192), 146 (5) Magstim 90 mm circular coil (P/N 3192), 146 (6) Magstim animal MST coil, (7) Magstim human MST coil (S/N MP39), (8) Brainsway H coil, 147 (9) Brainsway H1 coil, 76,8083,147 (10) H1 coil with frontal iron core, 79 (11) H1 coil with lateral iron core, 79 (12) Brainsway H1L coil, 80 (13) Brainsway H2 coil, 76,80,81,147 (14) Brainsway HADD coil, 116 (15) Magstim cap coil, (16) crown coil, 3 (17) crown coil with back-splayed winding, (18) crown coil with back-spaced winding, (19) supraorbital halo coil, 98,99 (20) MRI z-gradient coil in parallel-current (Helmholz) mode, 100 (21) 3-layer double coil, 62 (22) double butterfly, 56,58,59 (23) circular slinky-7 coil, 52,53 (24) rectangular slinky-7 coil, 12,53,54 (25) Magstim 25 mm figure-8 (P/N 1165), 21,146 (26) Cadwell Corticoil, 148 (27) Cadwell B-shaped coil, 21 (28) 50 mm V-coil, 13 (29) MagVenture C-B65 butterfly coil, 149 (30) MagVenture MC-B70 butterfly coil, 26,27,149 (31) Magstim 70 mm figure-8 coil (P/N 9925, 3190), 146 (32) 70 mm figure-8 with shielding plate, 65 (33) 70 mm figure-8 with active shield (5 turns), 69 (34) Neuronetics iron-core figure-8 coil (CRS 2100), 28,68 (35) MagVenture D-B80 butterfly coil, 27,149 (36) MagVenture MST twin coil, (37) Magstim double cone coil (P/N 9902), 146 (38) eccentric double cone coil with center-dense windings, (39) eccentric double cone coil with center-sparse windings, (40) stretched C-core coil, 3,68 (41) 3-D differential coil, 60 (42) 3-D coil array #1, 114 (43) 3-D coil array #2, 114 (44) 3-D coil array #3, 114 (45) Cadwell cloverleaf coil, 48,49 (46) circular coil array, 110,150 (47) Magstim 70 mm figure-8 coil in reversed-current mode, 15...…”
Section: Figurementioning
confidence: 99%
“…Simulation models of 50 TMS coil configurations: (1) Animal mini-coil, 145 (2) Magstim 50 mm circular coil (P/N 9999), 146 (3) 50 mm circular coil with iron core, 70 (4) Magstim 70 mm circular coil (P/N 3192), 146 (5) Magstim 90 mm circular coil (P/N 3192), 146 (6) Magstim animal MST coil, (7) Magstim human MST coil (S/N MP39), (8) Brainsway H coil, 147 (9) Brainsway H1 coil, 76,8083,147 (10) H1 coil with frontal iron core, 79 (11) H1 coil with lateral iron core, 79 (12) Brainsway H1L coil, 80 (13) Brainsway H2 coil, 76,80,81,147 (14) Brainsway HADD coil, 116 (15) Magstim cap coil, (16) crown coil, 3 (17) crown coil with back-splayed winding, (18) crown coil with back-spaced winding, (19) supraorbital halo coil, 98,99 (20) MRI z-gradient coil in parallel-current (Helmholz) mode, 100 (21) 3-layer double coil, 62 (22) double butterfly, 56,58,59 (23) circular slinky-7 coil, 52,53 (24) rectangular slinky-7 coil, 12,53,54 (25) Magstim 25 mm figure-8 (P/N 1165), 21,146 (26) Cadwell Corticoil, 148 (27) Cadwell B-shaped coil, 21 (28) 50 mm V-coil, 13 (29) MagVenture C-B65 butterfly coil, 149 (30) MagVenture MC-B70 butterfly coil, 26,27,149 (31) Magstim 70 mm figure-8 coil (P/N 9925, 3190), 146 (32) 70 mm figure-8 with shielding plate, 65 (33) 70 mm figure-8 with active shield (5 turns), 69 (34) Neuronetics iron-core figure-8 coil (CRS 2100), 28,68 (35) MagVenture D-B80 butterfly coil, 27,149 (36) MagVenture MST twin coil, (37) Magstim double cone coil (P/N 9902), 146 (38) eccentric double cone coil with center-dense windings, (39) eccentric double cone coil with center-sparse windings, (40) stretched C-core coil, 3,68 (41) 3-D differential coil, 60 (42) 3-D coil array #1, 114 (43) 3-D coil array #2, 114 (44) 3-D coil array #3, 114 (45) Cadwell cloverleaf coil, 48,49 (46) circular coil array, 110,150 (47) Magstim 70 mm figure-8 coil in reversed-current mode, 15...…”
Section: Figurementioning
confidence: 99%
“…Unfortunately, the large size of TMS coils prohibits implantation and until recently, the possibility of implanting smaller coils into the parenchyma was not considered viable because the fields induced by small coils were thought to be not strong enough to modulate neuronal activity. However, several recent studies have found that small coils [36], [37], including ones as small as 0.5 mm in diameter [36], could in fact activate neurons. Because such coils are small enough to be implanted, these findings raise the possibility that micromagnetic stimulation ( μ MS) could form the basis of one or more next-generation neural prosthetic devices.…”
Section: Introductionmentioning
confidence: 99%
“…To study the effect of stimulation parameters (magnitude and pulse width of coil current), many studies used frog sciatic nerve in in vitro experiments, [11], [15], [16]. Other studies focused on in vivo experiments, performing peripheral stimulation of rabbit sciatic nerve [7] and transcranial stimulation in behaving primates [17]. These experiments established stimulation thresholds in terms of stimulation voltage [11] or induced electric field magnitude [7].…”
Section: Introductionmentioning
confidence: 99%