2021
DOI: 10.1051/0004-6361/202040142
|View full text |Cite
|
Sign up to set email alerts
|

Millimeter- and submillimeter-wave spectrum of trans-formaldoxime (CH2NOH)

Abstract: Context. Among the six atoms of N-containing molecules with the formula of CH 3 NO, only formamide (H 2 NCHO), the most stable structural isomer, has been detected in the interstellar medium (ISM). The formaldoxime isomer may be formed, for example, by the reaction of formaldehyde (H 2 CO) or methanimine (H 2 CNH) and hydroxylamine (H 2 NOH), which are all detected in the ISM. The lack of high accuracy millimeter-and submillimeter-wave measurements hinders the astronomical search for formaldoxime. Aims. The ai… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

4
2
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 28 publications
4
2
0
Order By: Relevance
“…With the exception of D JK and h 3 , our calculation results are accord well with the experimental values at this theoretical level. The close agreement of D JK between our calculation and the results from Wu and Tan [16,19,20] can be found in table 9, however, there are significant differences between our results and those reported by Kaushik et al [43]. The relative error of D JK at B2PLYP/aug-cc-pVTZ theoretical level with the experimental value [20] is 4.34%, nevertheless, the corresponding relative error is 14.13% at the CCSD(T) theoretical level.…”
Section: Quartic and Sextic Centrifugal Distortion Constantssupporting
confidence: 83%
See 4 more Smart Citations
“…With the exception of D JK and h 3 , our calculation results are accord well with the experimental values at this theoretical level. The close agreement of D JK between our calculation and the results from Wu and Tan [16,19,20] can be found in table 9, however, there are significant differences between our results and those reported by Kaushik et al [43]. The relative error of D JK at B2PLYP/aug-cc-pVTZ theoretical level with the experimental value [20] is 4.34%, nevertheless, the corresponding relative error is 14.13% at the CCSD(T) theoretical level.…”
Section: Quartic and Sextic Centrifugal Distortion Constantssupporting
confidence: 83%
“…The close agreement of D JK between our calculation and the results from Wu and Tan [16,19,20] can be found in table 9, however, there are significant differences between our results and those reported by Kaushik et al [43]. The relative error of D JK at B2PLYP/aug-cc-pVTZ theoretical level with the experimental value [20] is 4.34%, nevertheless, the corresponding relative error is 14.13% at the CCSD(T) theoretical level. Besides, the relative error of h 3 between calculated and the experimental value [20] is approximately 14.59%, requiring further experiments to explain this phenomenon.…”
Section: Quartic and Sextic Centrifugal Distortion Constantssupporting
confidence: 83%