2008
DOI: 10.1007/s00776-008-1272-0
|View full text |Cite
|
Sign up to set email alerts
|

Midterm results of the Synergy cementless tapered stem: stress shielding and bone quality

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
12
1

Year Published

2010
2010
2017
2017

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 25 publications
(16 citation statements)
references
References 17 publications
3
12
1
Order By: Relevance
“…However, the most challenging issue is the stress shielding effect that can manifest in the proximal fit stem. Nishino et al 5) found that even with proximally fixed type stems, severe stress shielding occurred because of distal fixation. Engh et al 15) reported that stress shielding itself does not strongly affect the long-term results of THA, while Noble et al 16) found that the range and degree of stress shielding augmented during the postoperative course.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…However, the most challenging issue is the stress shielding effect that can manifest in the proximal fit stem. Nishino et al 5) found that even with proximally fixed type stems, severe stress shielding occurred because of distal fixation. Engh et al 15) reported that stress shielding itself does not strongly affect the long-term results of THA, while Noble et al 16) found that the range and degree of stress shielding augmented during the postoperative course.…”
Section: Discussionmentioning
confidence: 99%
“…For a clinical evaluation, using HHS, as well as interpret complications during and after surgery in all patients 5) . Radiographic evaluation was done through comparison between immediate postoperative radiographs and last follow-up radiographs.…”
Section: Methodsmentioning
confidence: 99%
“…However, most likely, there will be ARMD problems related to ASR LDH MoM THA surgery as well. The mid-term survival of the cementless Synergy stem has been 100% for average follow-up of 75 months (23). The results of the BHR cup have been published mainly when using the BHR as a hip resurfacing device.…”
Section: Discussionmentioning
confidence: 99%
“…Femoral bone loss or resorption, so-called stress shielding, around well-fixed femoral components is thought to occur around most, if not all, stem designs [12,32,34,38]. This phenomenon is reportedly exacerbated with fully coated stems [12,15,18].…”
Section: Introductionmentioning
confidence: 99%