2022
DOI: 10.1016/j.soisec.2022.100043
|View full text |Cite
|
Sign up to set email alerts
|

Mid-infrared spectroscopy for accurate measurement of an extensive set of soil properties for assessing soil functions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
23
2

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
2
1

Relationship

1
7

Authors

Journals

citations
Cited by 44 publications
(27 citation statements)
references
References 72 publications
2
23
2
Order By: Relevance
“…Apart from the difference in costs of the used instruments and the level of portability, there was no obvious benefit of vis-NIR system over mid-IR, or vice versa. The stated error estimates reported in this study and in earlier studies ( Table 1 ) [ 1 , 2 , 3 , 4 , 5 , 6 , 7 , 8 , 9 , 10 , 11 , 12 , 13 , 14 , 19 , 20 , 21 , 22 , 23 , 24 , 25 , 26 , 27 , 28 , 29 , 30 , 31 , 32 , 33 , 34 , 39 , 40 ] are higher than those corresponding to traditional analysis, where the laboratory method has a detection limit of 20 g kg −1 for sand and clay (dry basis), and generally, is reproducible to within ±80 g kg −1 , Ref. [ 49 ].…”
Section: Resultssupporting
confidence: 64%
See 2 more Smart Citations
“…Apart from the difference in costs of the used instruments and the level of portability, there was no obvious benefit of vis-NIR system over mid-IR, or vice versa. The stated error estimates reported in this study and in earlier studies ( Table 1 ) [ 1 , 2 , 3 , 4 , 5 , 6 , 7 , 8 , 9 , 10 , 11 , 12 , 13 , 14 , 19 , 20 , 21 , 22 , 23 , 24 , 25 , 26 , 27 , 28 , 29 , 30 , 31 , 32 , 33 , 34 , 39 , 40 ] are higher than those corresponding to traditional analysis, where the laboratory method has a detection limit of 20 g kg −1 for sand and clay (dry basis), and generally, is reproducible to within ±80 g kg −1 , Ref. [ 49 ].…”
Section: Resultssupporting
confidence: 64%
“…This suggests its wide usage in agricultural and environmental soil sensing applications. However, this is still being debated [ 15 , 16 , 17 , 18 , 19 , 20 , 21 , 22 , 23 ].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Many researchers have demonstrated the efficiency of soil spectroscopy and robust predictive capabilities for multiple soil properties [28], summarized in [7]. In addition, the MIR spectral range has been proven to provide superior prediction compared to vis-NIR-SWIR spectra [29][30][31]. The SSLs, thus, are important research initiatives [10] but the data are only available through scientific journal publications.…”
Section: Introduction and Contextualizationmentioning
confidence: 99%
“…This measure shows how well the variance of the predicted spectral values coincides with the values measured in the laboratory. R 2 is calculated according to the following formula (Ng et al 2022):…”
Section: Accuracy Assessmentmentioning
confidence: 99%