2019
DOI: 10.1364/oe.27.019282
|View full text |Cite
|
Sign up to set email alerts
|

Mid-infrared dual-comb spectroscopy with absolute frequency calibration using a passive optical reference

Abstract: We demonstrate an absolute-frequency-calibrated mid-infrared dual-comb spectrometer by using a reference absorption cell. The source is based on a singly-resonant OPO containing two MgO:PPLN crystals in a common ring cavity, synchronously pumped by two mode-locked Yb-fiber lasers. The repetition-rate of the two pumps are stabilized while their offset frequencies and the OPO cavity length are not actively controlled. The reference spectrum is used to correct the frequency fluctuations in the sample spectrum pro… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0

Year Published

2019
2019
2020
2020

Publication Types

Select...
3
2
1

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(14 citation statements)
references
References 26 publications
0
14
0
Order By: Relevance
“…The time-domain interferograms in the output of the two photodetectors are digitized, a Blackman apodization function is applied to the both (sample and reference) interferograms, and followed by a Fourier transformation to yield the corresponding absorption spectra. The apodization function is used to minimize the ringing effect around the (narrow) absorption lines 40 , which also limits the effective measurement time-window of each interferogram to ~120 μs around the central burst. Therefore, each individual interferogram is measured in 120 μs with a repetition period of 1/∆f rep (≈4 ms).…”
Section: Resultsmentioning
confidence: 99%
“…The time-domain interferograms in the output of the two photodetectors are digitized, a Blackman apodization function is applied to the both (sample and reference) interferograms, and followed by a Fourier transformation to yield the corresponding absorption spectra. The apodization function is used to minimize the ringing effect around the (narrow) absorption lines 40 , which also limits the effective measurement time-window of each interferogram to ~120 μs around the central burst. Therefore, each individual interferogram is measured in 120 μs with a repetition period of 1/∆f rep (≈4 ms).…”
Section: Resultsmentioning
confidence: 99%
“…For DCS, one pump comb had a slightly different repetition frequency (frep) with respect to the second comb, so that the difference in the repetition frequency (Δfrep) could be set between 200 to 300 Hz. A 10 MHz reference clock was used for referencing all of the frequency sources used in frep control electronics, triggering of the data acquisition, and modulating the discharge [30,50].…”
Section: Mid-infrared Dual-comb Sourcementioning
confidence: 99%
“…We use the optical frequency position of this reference absorption line for removing the fceo fluctuations and frequency calibration of the dual-comb spectrum. More details on absolute frequency calibration can be found in [50].…”
Section: Dual-comb Spectrometer Design For Absorption/dispersion Specmentioning
confidence: 99%
See 2 more Smart Citations