2009
DOI: 10.1016/j.molstruc.2009.01.046
|View full text |Cite
|
Sign up to set email alerts
|

Microwave spectra, r0 structural parameters, and conformational stability from xenon solutions of silylcyclohexane

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
12
0

Year Published

2010
2010
2023
2023

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 9 publications
(12 citation statements)
references
References 33 publications
0
12
0
Order By: Relevance
“…The experimentally obtained enthalpy difference value of 453 ( 38 cm -1 compares well with the value of 413 ( 22 cm -1 obtained by averaging the results of the four largest basis set calculations using the MP2(full) method. However, as we have seen in other enthalpy difference calculations, 6,10 the B3LYP method produces results that are significantly higher than the experimental value, regardless of basis set, with an average from the four highest basis sets of 627 ( 5 cm -1 (Table 4). The smallest basis sets [6-31G(d) and 6-31+G(d)] gave results that were very different from the higher level calculations and were omitted from the average.…”
Section: Discussionmentioning
confidence: 63%
See 4 more Smart Citations
“…The experimentally obtained enthalpy difference value of 453 ( 38 cm -1 compares well with the value of 413 ( 22 cm -1 obtained by averaging the results of the four largest basis set calculations using the MP2(full) method. However, as we have seen in other enthalpy difference calculations, 6,10 the B3LYP method produces results that are significantly higher than the experimental value, regardless of basis set, with an average from the four highest basis sets of 627 ( 5 cm -1 (Table 4). The smallest basis sets [6-31G(d) and 6-31+G(d)] gave results that were very different from the higher level calculations and were omitted from the average.…”
Section: Discussionmentioning
confidence: 63%
“…Additionally, the methyl-and silylcyclohexane studies were performed at low temperatures, and packing effects influence conformational preferences as the freezing point is approached. The difference between gas-phase and liquid-phase experimental determination can be seen 6,9 in the 100 cm -1 difference in the determined ∆H by the Raman study of the liquid and the infrared study of the xenon solution for silylcyclohexane.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations