2007
DOI: 10.1021/om061027f
|View full text |Cite
|
Sign up to set email alerts
|

Microwave Spectra and Gas-Phase Structural Parameters of Bis(η5-cyclopentadienyl)tungsten Dihydride

Abstract: Microwave spectra for 11 isotopomers of bis(η 5 -cyclopentadienyl)tungsten dihydride ((C 5 H 5 ) 2 WH 2 ) were recorded in the 5-14 GHz region using a Flygare-Balle-type pulsed beam spectrometer. Spectra arising from four tungsten isotopomers of both the (C 5 H 5 ) 2 WH 2 and (C 5 H 5 ) 2 WHD species and three W isotopomers for the (C 5 H 5 ) 2 WD 2 complex have been measured. The ∼250 b-type transition frequencies assigned for these near-prolate asymmetric top molecules were accurately described (σ fit ) 2-4 … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
44
0

Year Published

2009
2009
2015
2015

Publication Types

Select...
7
2
1

Relationship

5
5

Authors

Journals

citations
Cited by 48 publications
(45 citation statements)
references
References 58 publications
1
44
0
Order By: Relevance
“…Microwave measurements were made using a Flygare-Balle type pulsed-beam Fourier transform (PBFT) microwave spectrometer described previously. 21,22 The CPCA (95%) and FA (98%) samples were purchased from Sigma Aldrich and the FA-d 1 (99.2% d) was purchased from CDN isotopes; each sample was used without further purification. The samples were transferred to separate glass sample cells.…”
Section: Microwave Measurementsmentioning
confidence: 99%
“…Microwave measurements were made using a Flygare-Balle type pulsed-beam Fourier transform (PBFT) microwave spectrometer described previously. 21,22 The CPCA (95%) and FA (98%) samples were purchased from Sigma Aldrich and the FA-d 1 (99.2% d) was purchased from CDN isotopes; each sample was used without further purification. The samples were transferred to separate glass sample cells.…”
Section: Microwave Measurementsmentioning
confidence: 99%
“…The spectrometers are similar to the Flygare-Balle microwave spectrometer system, but employ homodyne (zero-IF) detection method, the details of which can be found in previous papers. 22,23 . Initial scans were made from 7200 to 6700 MHz covering the J″=0→J′ =1 a-dipole and b-dipole transitions using the low resolution transverse beam spectrometer.…”
Section: Methodsmentioning
confidence: 99%
“…This spectrometer was described previously. 20,21 The microwave pulses, for microwave transmit, tune the cavity and trigger the acquisition, and valve pulses are produced by custom boards that use transistor-transistor logic (TTL) off-the-shelf chips. The control of the spectrometer and these pulses is made in either manual or computer controlled mode.…”
Section: A Experimentalmentioning
confidence: 99%