“…Sample preparation for ICP-MS analysis 0.250g ± 0.0001 g of fresh samples where weighted with analytical balance in Teflon recipients, then 8 ml concentrated ultrapure HNO 3 (65%) and 2 ml H 2 O 2 30% were added and were subjected to mineralization by microwave digestion (30 min.) with ETHOS UP microwave digestion system, then the clear solutions were transferred quantitatively into the volumetric flasks (50 mL) and made up with Milli-Q ultrapure water (2 repetitions) (Milestone ETHOS UP Digestion Apps, Zovinka and Stock 2010) The Agilent Series ICP-MS spectrometer with quadrupole analyzer 7700x and MassHunter Workstation software (Agilent Technologies) was used in the analysis of the two varieties of basil and peppermint variety after acidic digestion (65% ultrapure nitric acid). The calibration curve was performed with ICP-MS multi-element calibration standard (1000 mg/L of Fe, K, Ca, Na, Mg; 100 mg/L of Sr; 10 mg/L of Ag, Al, As, Ba, Be, Cd, Co, Cr, Cu, Mn, Mo, Ni, Pb, Sb, Se, Tl, V, Zn, Th, U in 5% HNO3) (Sannac et al, 2017;Pacquette et al, 2015;Liba et al, 2014)…”