2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) 2014
DOI: 10.1109/nssmic.2014.7430745
|View full text |Cite
|
Sign up to set email alerts
|

Microstructured semiconductor neutron detector (MSND)-based Helium-3 Replacement technology

Abstract: The present work employs MSND technology as a 3 He gas-tube direct-replacement technology. The MSND-based Helium Replacement (HeRep) is a single instrument utilizing thirty 4-cm 2 active area MSNDs to directly replace 3 He-based proportional neutron counters. The HeRep Mk II prototype yielded 102.71±0.84% of the neutron detection efficiency of a 4-atm Reuter Stokes 3 He gas-filled detector with the same active dimensions and test setup from a 252 Cf source. The HeRep Mk II matched the efficiency of the 3 He de… Show more