2020
DOI: 10.1016/j.jma.2020.02.007
|View full text |Cite
|
Sign up to set email alerts
|

Microstructural, mechanical and corrosion characterization of an as-cast Mg–3Zn–0.4Ca alloy for biomedical applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
9
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 46 publications
(11 citation statements)
references
References 43 publications
0
9
0
Order By: Relevance
“…The flexural strain was calculated according to Equation (3): where D is the maximum deflection of the center of the substrate, d is the height of the sample, and L is the support span length. To obtain the flexural stress Equation (4) was used: where F is the maximum load and b is the width of the tested sample [ 31 , 32 ].…”
Section: Methodsmentioning
confidence: 99%
“…The flexural strain was calculated according to Equation (3): where D is the maximum deflection of the center of the substrate, d is the height of the sample, and L is the support span length. To obtain the flexural stress Equation (4) was used: where F is the maximum load and b is the width of the tested sample [ 31 , 32 ].…”
Section: Methodsmentioning
confidence: 99%
“…Not only do Mg alloys exhibit excellent biocompatibility and natural biodegradability, they also exhibit low density (1.7-2.0 g/cm 3 ) and strength in excess of 250 MPa. Notably, the elastic moduli of Mg-based alloys (40)(41)(42)(43)(44)(45) are better compared to the stiffness of cortical bones (3)(4)(5)(6)(7)(8)(9)(10)(11)(12)(13)(14)(15)(16)(17)(18)(19)(20) than those of conventional metallic materials used as permanent implants (c.f., ~200 GPa for stainless steel, ~230 GPa for cobalt-based alloys, and ~115 GPa for titanium alloys [10]), which helps to eliminate the stress-shielding effect hindering the healing process.…”
Section: Introductionmentioning
confidence: 99%
“…Among hundreds of Mg-based alloy compositions proposed for orthopaedic applications, tertiary Mg-Zn-X alloys are by far the most studied due to their outstanding properties profile, both in vitro and in vivo. Ca, Y, and Zr are by far the most popular additions to Mg-Zn systems when seeking a balanced combination of mechanical and biofunctional properties [11][12][13][14][15][16][17][18][19][20][21][22][23]. The commercial alloy ZK60 has been proven versatile enough for processing by various techniques, from conventional extrusion and rolling to a wide range of severe plastic deformation techniques, resulting in substantial microstructure refinement and the enhancement of tensile [24], fatigue [25] and corrosion properties [26][27][28].…”
Section: Introductionmentioning
confidence: 99%
“…Biomaterials are considered non-viable materials used in medical devices for centuries and are intended to interact with biological systems. 1,2 These materials develop various biomedical devices to provide the necessary healing effect to the injured tissues. However, most biomedical devices have been used predominantly for healing bone tissues.…”
Section: Introductionmentioning
confidence: 99%