2011
DOI: 10.1016/j.cemconcomp.2011.05.011
|View full text |Cite
|
Sign up to set email alerts
|

Microscopic analysis of paste and aggregate distresses in pervious concrete in a wet, hard freeze climate

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
16
0
2

Year Published

2013
2013
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 49 publications
(21 citation statements)
references
References 8 publications
2
16
0
2
Order By: Relevance
“…Slika 4. Tipičan poprečni presek sistema propusnog betona od elemenata sa žljebovima za spajanje [25] Figure 4. Typical cross-section of permeable interlocking concrete pavement [25] Slojevi sistema tipičnog poprečnog preseka propusnog betona sa žljebovima za spajanje na slici 4, odozgo na dole su: elementi od propusnog betona sa žljebovima za spajanje, propusni materijal između napred navedenih elemenata, posteljica od krupnog agregata, rezervoar od krupnog agregata u osnovnom sloju, rezervoar od krupnog agregata u sloju ispod osnovnog (sa cevi za odvodnjavanje, ako je potrebno), geotehnički materijal (opcionalno) i tlo.…”
Section: Permeable Interlocking Concrete Pavementsunclassified
See 1 more Smart Citation
“…Slika 4. Tipičan poprečni presek sistema propusnog betona od elemenata sa žljebovima za spajanje [25] Figure 4. Typical cross-section of permeable interlocking concrete pavement [25] Slojevi sistema tipičnog poprečnog preseka propusnog betona sa žljebovima za spajanje na slici 4, odozgo na dole su: elementi od propusnog betona sa žljebovima za spajanje, propusni materijal između napred navedenih elemenata, posteljica od krupnog agregata, rezervoar od krupnog agregata u osnovnom sloju, rezervoar od krupnog agregata u sloju ispod osnovnog (sa cevi za odvodnjavanje, ako je potrebno), geotehnički materijal (opcionalno) i tlo.…”
Section: Permeable Interlocking Concrete Pavementsunclassified
“…kišnice [39,40,41]. 4. When porous concrete is correctly designed, it can have compressive strength higher than 50 MPa, hydraulic conductivity higher than 1 mm/s and the required frost resistance.…”
Section: Zaključcimentioning
confidence: 99%
“…During the freezing/thawing cycles, the pore water changes into ice, and these ices can displace sandy soil particles, disrupting the interlocking of sandy soil particles, dilating the pore volume, and increasing microcracks' size. However, the increased pore volume and propagation of microcracks through the interfacial transition zone between paste and aggregates cannot fully recover due to the existence of cohesion in sandy soil particles at the time that the ices melt [36,37]. erefore, the cyclic thawing/freezing process can reduce the compressive strength and weight of the brick specimens.…”
Section: Bulk Density Of the Un Red Bricksmentioning
confidence: 99%
“…al., [22] in another study. As a result of the investigation, it is found out that freeze/thaw distresses were the suspected cause of a majority of the subsurface cracks due to the similarity of the cracking patterns in the previous concrete to cracking patterns in conventional concrete that were caused by freeze/thaw damage.…”
Section: Introductionmentioning
confidence: 99%