2018
DOI: 10.1088/1742-6596/986/1/012022
|View full text |Cite
|
Sign up to set email alerts
|

Microsacle PolySilicon Hemispherical Shell Resonating Gyroscopes with Integrated Three-dimensional Curved Electrodes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
8
1

Year Published

2019
2019
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(9 citation statements)
references
References 4 publications
0
8
1
Order By: Relevance
“…Wan et al [ 143 , 144 ] and Zhuang et al [ 145 , 146 ] used polysilicon to fabricate a micro- HRG using the same method as Bernstein et al [ 134 , 135 ]. The advantages of this method include elimination of the extra assembly process due to simultaneous fabrication of the shell and resonator, a simple fabrication method, and a large transduction area with a small and uniform gap size due to anchorage of the shell at the center with uniform circumferential electrodes.…”
Section: Microscale Hrg Fabrication Methods and Materialsmentioning
confidence: 99%
See 1 more Smart Citation
“…Wan et al [ 143 , 144 ] and Zhuang et al [ 145 , 146 ] used polysilicon to fabricate a micro- HRG using the same method as Bernstein et al [ 134 , 135 ]. The advantages of this method include elimination of the extra assembly process due to simultaneous fabrication of the shell and resonator, a simple fabrication method, and a large transduction area with a small and uniform gap size due to anchorage of the shell at the center with uniform circumferential electrodes.…”
Section: Microscale Hrg Fabrication Methods and Materialsmentioning
confidence: 99%
“…The advantages of this method include elimination of the extra assembly process due to simultaneous fabrication of the shell and resonator, a simple fabrication method, and a large transduction area with a small and uniform gap size due to anchorage of the shell at the center with uniform circumferential electrodes. The performance of the resonator as a gyro in force-rebalance mode showed a frequency mismatch of 0.51 Hz, and a bias stability of 21.8 deg./h [ 144 ], while Zhuang et al [ 145 ] reported performance of an HRG in open-loop mode with a resonance frequency of 28 kHz, a frequency mismatch of 0.009%, and a bias stability of 80 deg./h.…”
Section: Microscale Hrg Fabrication Methods and Materialsmentioning
confidence: 99%
“…According to the working principle of resonators, accurate measurement of the resonance frequency of micro resonators is crucial [11]. The main methods for measuring the resonance frequency of micro resonators are electrical measurement and measurement based on laser Doppler vibrometer (LDV) [12][13][14]. Electrical measurement requires that the resonator has conductivity.…”
Section: Introductionmentioning
confidence: 99%
“…One is via chemical vapor deposition (CVD) on the hemispherical cavity, the other is via a blowing process. As for the CVD approach, a 3D micro-hemispherical shell structure could be fabricated by depositions of polysilicon [ 9 ], diamond [ 10 ], and silicon oxide [ 4 ] on isotropically etched cavities, or poly-crystalline diamond [ 11 ] on a micro-electro-discharge machining cavity. The gap between the shell and electrode is usually determined by the thickness of the sacrifice layer, which can be precisely controlled.…”
Section: Introductionmentioning
confidence: 99%