2022
DOI: 10.1016/j.scitotenv.2022.155989
|View full text |Cite
|
Sign up to set email alerts
|

Microplastic atmospheric dustfall pollution in urban environment: Evidence from the types, distribution, and probable sources in Beijing, China

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 73 publications
1
4
0
Order By: Relevance
“…The number of AMPs in Bandung and Osaka decreased as the size of the physical diameter of AMPs increased. This is in accordance with AMPs research in Wenzhou, which shows that the number of AMPs decreases as the size of the physical diameter of AMPs increases with the majority of AMPs having a physical diameter < 30 μm [40] AMPs research in Beijing also shows that the number of AMPs decreases as the physical diameter of AMPs increases with the majority of AMPs having a physical diameter between 20 -100 μm [46].…”
Section: Amps Size Distributionsupporting
confidence: 85%
“…The number of AMPs in Bandung and Osaka decreased as the size of the physical diameter of AMPs increased. This is in accordance with AMPs research in Wenzhou, which shows that the number of AMPs decreases as the size of the physical diameter of AMPs increases with the majority of AMPs having a physical diameter < 30 μm [40] AMPs research in Beijing also shows that the number of AMPs decreases as the physical diameter of AMPs increases with the majority of AMPs having a physical diameter between 20 -100 μm [46].…”
Section: Amps Size Distributionsupporting
confidence: 85%
“…An LDIR (Agilent 8700) analyzer was used to detect MPs in soil samples (Liu et al, 2022). The 8700 LDIR laser infrared imaging system uses a quantum cascade laser as the light source; the energy is more than 10,000 times that of the traditional Fourier transform microinfrared/infrared imaging system.…”
Section: Methodsmentioning
confidence: 99%
“…Deposited particles are collected by rinsing the device with ultrapure water and filtering. Some studies collect the deposited dust over a clean glass Petri dish [51,53,65,75] or in specific areas using bristle brushes and metal dustpans [57,58,73] or a vacuum cleaner [93,94]. In addition, plant leaves [86] and spider nets [54] are also used as samplers for atmospheric MPs deposition studies.…”
Section: Revised Sampling Methodsmentioning
confidence: 99%
“…The deposition area is essential in calculating the number of MPs atmospheric deposition per unit area [34,41]. For deposited dust, the MPs abundance is measured in units per gram of dust fall [36,57,58,73].…”
Section: Revised Sampling Methodsmentioning
confidence: 99%