2020
DOI: 10.1063/1.5134947
|View full text |Cite
|
Sign up to set email alerts
|

Microplasma emission spectroscopy of carbon dioxide using the carbon monoxide Ångström system

Abstract: The present paper describes a system and method for indirect emission spectroscopy of CO2 in the visible spectrum. This is achieved by using a microplasma spectrometer that first converts CO2 into CO and then measures emissions from the CO Ångström system (B1Σ + → A1Π) at 560 nm. The experiments were performed on gaseous samples of CO2, mixed in both N2 and air, to concentrations between 0.01% and 100%. In addition to the microplasma spectrometer, the process was monitored by mass spectrometry with a residual … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
23
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 8 publications
(24 citation statements)
references
References 16 publications
0
23
1
Order By: Relevance
“…We have previously reported a microplasma based system for optical emission spectroscopy of CO2 [4]. This system utilizes both the physics and the chemistry of the plasma, where CO2 first is converted to CO in a chemical process, after which optical emissions from the CO Ångström system are recorded by a spectrometer.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…We have previously reported a microplasma based system for optical emission spectroscopy of CO2 [4]. This system utilizes both the physics and the chemistry of the plasma, where CO2 first is converted to CO in a chemical process, after which optical emissions from the CO Ångström system are recorded by a spectrometer.…”
Section: Introductionmentioning
confidence: 99%
“…Even though the emission process is very specific, the conversion process is not, and may vary depending on the composition of the sample. For example, the conversion process was shown to be significantly influenced by the presence of O2 [4].…”
Section: Introductionmentioning
confidence: 99%
“…The complete system is thoroughly described by Persson and Berglund. 19 Before a measurement began, the OES system was initialized and allowed to stabilize for >30 min. Then, the capillary was inserted into the patch, aer which the OES system was allowed to stabilize for another minute, before the patch was attached to one of the authors' lower arm with a piece of tape.…”
Section: System Evaluationmentioning
confidence: 99%
“…The data was recorded and analyzed by the same soware used by Persson and Berglund, 19 where the CO 2 content of the sample was estimated by studying the 0-3 band of the CO Angström system. The intensity of this emission bandcentered at 560 nmwas linearly dependent on the CO 2 content.…”
Section: System Evaluationmentioning
confidence: 99%
See 1 more Smart Citation