2020
DOI: 10.1007/s00418-020-01868-8
|View full text |Cite
|
Sign up to set email alerts
|

Micrometer-resolution X-ray tomographic full-volume reconstruction of an intact post-mortem juvenile rat lung

Abstract: In this article, we present an X-ray tomographic imaging method that is well suited for pulmonary disease studies in animal models to resolve the full pathway from gas intake to gas exchange. Current state-of-the-art synchrotron-based tomographic phase-contrast imaging methods allow for three-dimensional microscopic imaging data to be acquired non-destructively in scan times of the order of seconds with good soft tissue contrast. However, when studying multi-scale hierarchically structured objects, such as the… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
26
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 28 publications
(26 citation statements)
references
References 57 publications
0
26
0
Order By: Relevance
“…Own preliminary data point to the same result. We imaged an entire rat lung in situ immediately post mortem using high-resolution synchrotron radiation based X-ray tomographic microscopy [44]. A rst analysis of regional di erence shows similar results as mentioned above.…”
Section: Discussionmentioning
confidence: 59%
“…Own preliminary data point to the same result. We imaged an entire rat lung in situ immediately post mortem using high-resolution synchrotron radiation based X-ray tomographic microscopy [44]. A rst analysis of regional di erence shows similar results as mentioned above.…”
Section: Discussionmentioning
confidence: 59%
“…Own preliminary data point to the same result. We imaged an entire rat lung in situ immediately post mortem using high-resolution synchrotron radiation based X-ray tomographic microscopy [ 47 ]. A first analysis of regional difference shows similar results as mentioned above.…”
Section: Discussionmentioning
confidence: 99%
“…The image on the scintillator was magnified 4 times using a high numerical aperture macroscope custom built by Optique Peter (Lentilly, France) [ 24 ] and captured using a pco.EDGE 5.5 (PCO AG, Kelheim, Germany) sCMOS camera, resulting in an effective isometric pixel size of 1.625 μm. 3–7 wide-field 360-degree scans were stacked vertically with slight overlaps along the rotational axis [ 25 27 ] for each sample to capture its complete volume. Tomographic reconstructions of the individual 3D-datasets were performed in single-distance phase contrast mode [ 28 ] (δ = 2e-7, β = 2.8e-10) with the gridrec algorithm [ 29 ] using the TOMCAT reconstruction pipeline (Reco Manager) [ 30 ], and finally stitched together using the non-rigid stitching algorithm NRStitcher [ 31 ].…”
Section: Methodsmentioning
confidence: 99%