2022
DOI: 10.1101/2022.11.17.516871
|View full text |Cite
Preprint
|
Sign up to set email alerts
|

Microlenses fabricated by two-photon laser polymerization for cell imaging with non-linear excitation microscopy

Abstract: Non-linear excitation microscopy offers a number of advantages for in vivo imaging compared to conventional confocal techniques. However, tissue penetration can still be an issue due to both scattering and spherical aberrations induced on highly focused beams by the tissue. The use of low numerical aperture objectives to pass through the outer layers of the skin, together with high dioptric power microlenses implanted in-vivo close to the observation volume, can be beneficial to the reduction of the optical ab… Show more

Help me understand this report
View published versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
1
1
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 51 publications
(151 reference statements)
0
2
0
Order By: Relevance
“…This procedure leads to a 98% reduction in the fabrication time with respect to volume polymerization, still obtaining sufficient optical quality to use the lenses for direct wide-field imaging of cells, both in transmission and in fluorescence mode. We also show that the microlenses can be simply coupled to a raster scanning non-linear excitation optical microscope, even by using low numerical aperture and low magnification objectives in a virtual image coupling configuration [5]. By changing the distance between the microscope objective and the microlenses we can tune the depth of focal plane in the sample to which the microlenses are directly coupled.…”
Section: Resultsmentioning
confidence: 97%
“…This procedure leads to a 98% reduction in the fabrication time with respect to volume polymerization, still obtaining sufficient optical quality to use the lenses for direct wide-field imaging of cells, both in transmission and in fluorescence mode. We also show that the microlenses can be simply coupled to a raster scanning non-linear excitation optical microscope, even by using low numerical aperture and low magnification objectives in a virtual image coupling configuration [5]. By changing the distance between the microscope objective and the microlenses we can tune the depth of focal plane in the sample to which the microlenses are directly coupled.…”
Section: Resultsmentioning
confidence: 97%
“…Micro-spectrometers [32] and holograms [33], as well as non-linear imaging applications [34] where compact dimensions are well integrated with multiple functionalities may also obtain considerable improvement.…”
Section: Discussionmentioning
confidence: 99%