2021
DOI: 10.1016/j.foodchem.2020.128773
|View full text |Cite
|
Sign up to set email alerts
|

Microfluidic colorimetric analysis system for sodium benzoate detection in foods

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
16
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
3

Relationship

2
7

Authors

Journals

citations
Cited by 31 publications
(16 citation statements)
references
References 37 publications
0
16
0
Order By: Relevance
“…Moreover, 21 types of commercial food products were tested with reliable results . As shown in Figure A, Ko et al embedded two layers of acetophenone and acetone in the detection area of the wax-printed μPAD to react with the nitro compound generated by the reaction of sodium benzoate with sodium hydroxide (NaOH) to cause a colorimetric reaction . Then, the image of the reaction was transmitted to a smartphone and the sodium benzoate concentration was obtained through the self-developed analysis software.…”
Section: Application Of μPads In the Detection Of Chemical Hazards In...mentioning
confidence: 99%
See 1 more Smart Citation
“…Moreover, 21 types of commercial food products were tested with reliable results . As shown in Figure A, Ko et al embedded two layers of acetophenone and acetone in the detection area of the wax-printed μPAD to react with the nitro compound generated by the reaction of sodium benzoate with sodium hydroxide (NaOH) to cause a colorimetric reaction . Then, the image of the reaction was transmitted to a smartphone and the sodium benzoate concentration was obtained through the self-developed analysis software.…”
Section: Application Of μPads In the Detection Of Chemical Hazards In...mentioning
confidence: 99%
“…However, the immunological detection methods bear the risk of easy inactivation of antibodies, and the sensitivity of its detection to strong toxic pesticide residues also needs improvement. Therefore, the development of new recognition molecules, such as aptamers that are selected in actual samples, 127 Copyright 2021, with permission from Elsevier. (B) Illustration of a μPAD for the simultaneous detection of Hg 2+ and Ag + based on the conformational changes of the specific aptamers.…”
Section: ■ Overview Of μPadsmentioning
confidence: 99%
“… 13 Very recently, the employment of a microfluidic colorimetric analysis system for detecting sodium benzoate was presented, where the involved colour variation was modelled with linear expression with respect to the analyte concentration featuring the sound determination coefficient of R 2 = 0.997. 14 Unfortunately, it was necessary for the colorimetric reaction to be initiated at 120 °C, which is a major disadvantage for its practical utilization.…”
Section: Introductionmentioning
confidence: 99%
“…Paper-based analytical devices (μPADs) have a high integration capability and good biocompatibility and have found extensive utilization in various fields in the recent years, such as biomedicine, environmental monitoring, food science, pharmaceuticals, drug development, and more [ 51 , 52 , 53 , 54 , 55 , 56 , 57 , 58 ]. In clinical applications, paper-based devices have many advantages over the benchtop techniques described above, including a significantly lower cost, faster throughput, simpler operation, lower reagent consumption, and greater portability [ 59 , 60 , 61 , 62 ].…”
Section: Introductionmentioning
confidence: 99%