Our system is currently under heavy load due to increased usage. We're actively working on upgrades to improve performance. Thank you for your patience.
2022
DOI: 10.1089/ast.2021.0182
|View full text |Cite
|
Sign up to set email alerts
|

Microfluidic Chromatography for Enhanced Amino Acid Detection at Ocean Worlds

Abstract: Increasing interest in the detection of biogenic signatures, such as amino acids, on icy moons and bodies within our solar system has led to the development of compact in situ instruments. Given the expected dilute biosignatures and high salinities of these extreme environments, purification of icy samples before analysis enables increased detection sensitivity. Herein, we outline a novel compact cation exchange method to desalinate proteinogenic amino acids in solution, independent of t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(8 citation statements)
references
References 81 publications
(92 reference statements)
0
6
0
Order By: Relevance
“…To further test the multianalyte extraction, the 1 μM solution was diluted 1 in 10 in IO before extraction on Oasis MCX columns; this is 1000× lower concentrations than previous mixed amino acids extractions from ocean water. 31 To concentrate the analytes for the subsequent LC-MS analysis, the fractions were vacuum-dried after collection and reconstituted in 50 μL, providing a 10× concentration factor for the analysis. To avoid a high concentration of NaOH in these reconstituted fractions, elutions were performed using NH 4 OH solutions for both the pre-elute and elution steps.…”
Section: Mixed Analytesmentioning
confidence: 99%
See 3 more Smart Citations
“…To further test the multianalyte extraction, the 1 μM solution was diluted 1 in 10 in IO before extraction on Oasis MCX columns; this is 1000× lower concentrations than previous mixed amino acids extractions from ocean water. 31 To concentrate the analytes for the subsequent LC-MS analysis, the fractions were vacuum-dried after collection and reconstituted in 50 μL, providing a 10× concentration factor for the analysis. To avoid a high concentration of NaOH in these reconstituted fractions, elutions were performed using NH 4 OH solutions for both the pre-elute and elution steps.…”
Section: Mixed Analytesmentioning
confidence: 99%
“…Another major issue is the salt to amino acid ratios used for the extractions. The work by Van Volkenburg et al only achieved 17% recovery of phenylalanine as the salt:AA ratio increased to 500:1. Low recovery is due to analytes not being captured from the load solution, loss during the wash step, or failure to elute, but the underlying issues were not fully explored in this work.…”
Section: Introductionmentioning
confidence: 97%
See 2 more Smart Citations
“…Examples of applications for planetary science applications include desalting of samples containing amino acids on a microchip (Craft et al, 2020;Volkenburg et al, 2022), on-line preconcentration of amino acids before chromatographic analysis (Abrahamsson et al, 2021), and refocusing of extracted analytes for on-line extraction and chromatography (Abrahamsson et al, 2019).…”
Section: Solid-phase Extractionmentioning
confidence: 99%